Back Button BQ2007STR Datasheet HTML 4Page - Texas Instruments BQ2007STR Datasheet HTML 5Page - Texas Instruments BQ2007STR Datasheet HTML 6Page - Texas Instruments BQ2007STR Datasheet HTML 7Page - Texas Instruments BQ2007STR Datasheet HTML 8Page - Texas Instruments BQ2007STR Datasheet HTML 9Page - Texas Instruments BQ2007STR Datasheet HTML 10Page - Texas Instruments BQ2007STR Datasheet HTML 11Page - Texas Instruments BQ2007STR Datasheet HTML 12Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 16 page
background image
VCC(VMCV). The bq2007 charges fixed-cell battery packs
of N cells. The battery voltage divider is set by the di-
vider ratio equation:
R1
N
R22
1
=−
()
Note:
The resistor-divider network impedance
should be above 200K
Ω to protect the bq2007.
When battery temperature is monitored for maximum
and minimum allowable limits, the bq2007 requires that
the thermistor used for temperature measurement have
a negative temperature coefficient. See Figure 2.
Temperature and Voltage
Prequalifications
For charging to be initiated, the battery temperature
must fall within predetermined acceptable limits. The
voltage on the TS pin (VTS) is compared to an internal low-
temperature fault threshold (VLTF) of (0.5
∗ VCC) and the
high temperature cutoff voltage (VTCO) on the TCO pin. For
charging to be initiated, VTS must be less than VLTF and
greater than VTCO. Since VTS decreases as temperature
increases, the TCO threshold should be selected to be lower
than 0.5
∗ VCC for proper operation. If the battery
temperature is outside these limits, the bq2007 holds the
charge-pending state with a pulse trickle current until the
temperature is within limits. Temperature prequalification
and termination is disabled if VTS is greater than 0.8
∗ VCC.
See Figure 2.
The bq2007 provides undervoltage battery protection by
trickle-current conditioning of a battery that is below
the low-voltage threshold (VEDV). The battery voltage
(VCELL) is compared to the low-voltage threshold (VEDV)
and charge will be inhibited if VCELL <VEDV. The condi-
tion trickle current and fault time-out are a percentage
of the fast charge rate and maximum time-out (MTO).
Initiating Charge Action and
Discharge-Before-Charge
A charge action is initiated under control of: (1) battery
insertion or (2) power applied. Battery insertion is
detected when the voltage at the BAT pin falls from
above VMCV to below VMCV. Power applied is detected
by the rising edge of VCC when a battery is inserted.
Discharge-before-charge (see Figure 3) is initiated auto-
matically on application of power or battery insertion
when DCMD is connected to VSS. Discharge-on-demand
8
SLUS076A – JULY 2000
bq2007
FG200701.eps
bq2007
VCC
BAT
R1
N
T
C
bq2007
VCC
TS
SNS
SNS
BAT Voltage Connection
Thermistor Connection
R2
NTC = negative temperature coefficient thermistor.
VSS
RSNS
VSS
RSNS
Figure 2. Voltage and Temperature Limit Measurement
bq2007
bq2007
DCMD
Always Discharge
Discharge on
Command
DCMD
Figure 3. Discharge-Before-Charge



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com