Back Button MS1003SH Datasheet HTML 3Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 4Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 5Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 6Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 7Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 8Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 9Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 10Page - Shindengen Electric Mfg.Co.Ltd MS1003SH Datasheet HTML 11Page - Shindengen Electric Mfg.Co.Ltd Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 41 page
background image
MS1003SH・MS1004SH
Application Note Ver.2.2
SHINDENGEN ELECTRIC MFG. CO. , LTD
7/41
3. Circuit operation
3.1 Startup
The diagram below shows the startup sequence.
Startup sequence
3.1.1 Startup circuit
The startup circuit does not require a startup resistor,
making it possible to easily start the IC with a small
number of components. A schematic diagram of the
startup circuit is shown to the right.
Until the IC starts up, the startup circuit current Icc
(stup) flows from the Vin pin to the Vcc pin to charge
C, as shown in the diagram.
Oscillation begins when the voltage at the Vcc pin
reaches Vcc (start). The startup circuit opens, and the
startup circuit current stops. The Vcc pin has hysteresis,
which begins oscillating at Vcc (start) and stops
oscillating at Vcc (stop stby) or Vcc (stop normal). A
bias assist function is provided for the Vcc voltage to ensure safe startup. For more information on the bias
assist function, see Section 3.1.3.
Vin
Nc coil
backup
Vcc
VccUVLO
Startup
UVLO
Standby
Vcc(start)=
Vcc(stup off)=12V
Off
On
Normal mode
Standby mode
Vcc(stop normal)=8V
Vcc(stop on normal)=9V
Vcc(stup on stby)=8V
Vcc(stop stby)=12V
Off
On
Off
On
Off
On
Normal mode
Startup circuit
Vcc pin
Vin pin



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com