Back Button MT9V024 Datasheet HTML 32Page - ON Semiconductor MT9V024 Datasheet HTML 33Page - ON Semiconductor MT9V024 Datasheet HTML 34Page - ON Semiconductor MT9V024 Datasheet HTML 35Page - ON Semiconductor MT9V024 Datasheet HTML 36Page - ON Semiconductor MT9V024 Datasheet HTML 37Page - ON Semiconductor MT9V024 Datasheet HTML 38Page - ON Semiconductor MT9V024 Datasheet HTML 39Page - ON Semiconductor MT9V024 Datasheet HTML 40Page - ON Semiconductor  
Zoom Inzoom in Zoom Outzoom out
 38 / 40 page
background image
MT9V024/D
www.onsemi.com
38
Appendix A: Power−On Reset and Standby Timing
There are no constraints concerning the order in which the
various power supplies are applied; however, the MT9V024
requires reset to operate properly at power−up. Refer to
Figure 50 for the power−up, reset, and standby sequences.
Low−Power
Non−Low−Power
Non−Low−Power
Active
Pre−Standby
Standby
Active
Wake
up
Power
down
MIN 20 SYSCLK cycles
Note 3
MIN 20 SYSCLK cycles
MIN 20 SYSCLK cycles
Does not
respond to
serial
Interface
when
STANDBY=1
DOUT [9:0]
Driven = 0
Driven = 0
Power
up
VDD, VDDLVDS,
VAA, VAAPIX
RESET_BAR
STANDBY
SYSCLK
MIN 10 SYSCLK cycles
SCLK, SDATA
Twi−wire Serial I/F
DOUT [9:0]
DATA OUTPUT
Figure 50. Power−up, Reset, Clock, and Standby Sequence
NOTES: 1
. All output signals are defined during initial power−up with RESET_BAR held LOW without SYSCLK being active. To
properly reset the rest of the sensor, during initial power−up, assert RESET_BAR (set to LOW state) for at least 750ns
after all power supplies have stabilized and SYSCLK is active (being clocked). Driving RESET_BAR to LOW state does
not put the part in a low power state.
2. Before using two−wire serial interface, wait for 10 SYSCLK rising edges after RESET_BAR is de−asserted.
3. Once the sensor detects that STANDBY has been asserted, it completes the current frame readout before entering
standby mode. The user must supply enough SYSCLKs to allow a complete frame readout. See Table 2, “Frame Time,”
for more information
4. In standby, all video data and synchronization output signals are driven to a low state.
5. In standby, the two−wire serial interface is not active.
APPENDIX B: ELECTRICAL IDENTIFICATION
OF CFA TYPE
In order to identify the CFA type (RGB Bayer,
Monochrome, RCCC) that a specific MT9V024 has been,
the following table may be used.
CFA
R0x6B[11:9]
R0x6B[8:0]
RGB
6
4
RCCC
5
4
Mono
0
4



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com