20 / 29 page ![]() Data Sheet AD7927 Rev. D | Page 19 of 28 MODES OF OPERATION The AD7927 has a number of different modes of operation, which are designed to provide flexible power management options. These options can be chosen to optimize the power dissipation/throughput rate ratio for differing application requirements. The mode of operation of the AD7927 is con- trolled by the power management bits, PM1 and PM0, in the control register, as detailed in Table 8. When power supplies are first applied to the AD7927, care should be taken to ensure that the part is placed in the required mode of operation (see the Powering Up the AD7927 section). NORMAL MODE (PM1 = PM0 = 1) This mode is intended for the fastest throughput rate perform- ance because the user does not have to worry about any power- up times with the AD7927 remaining fully powered at all times. Figure 21 shows the general diagram of the operation of the AD7927 in this mode. The conversion is initiated on the falling edge of CS and the track- and-hold enters hold mode as described in the Serial Interface section. The data presented to the AD7927 on the DIN line during the first 12 clock cycles of the data transfer are loaded into the control register (provided the WRITE bit is 1). If data is to be written to the shadow register (SEQ = 0, SHADOW = 1 on the previous write), data presented on the DIN line during the first 16 SCLK cycles is loaded into the shadow register. The part remains fully powered up in normal mode at the end of the conversion as long as PM1 and PM0 are set to 1 in the write transfer during that conversion. To ensure continued operation in normal mode, PM1 and PM0 are both loaded with 1 on every data transfer. Sixteen serial clock cycles are required to complete the conversion and access the conversion result. The track-and-hold goes back into track on the 14th SCLK falling edge. CS may then idle high until the next conversion or may idle low until sometime prior to the next conversion (effectively idling CS low). For specified performance, the throughput rate should not exceed 200 kSPS, which means there should be no less than 5 μs between consecutive falling edges of CS when converting. The actual frequency of SCLK used determines the duration of the conversion within this 5 μs cycle; however, once a conversion is complete and CS has returned high, a minimum of the quiet time, tQUIET, must elapse before bringing CS low again to initiate another conversion. 1 12 SCLK DOUT DIN 16 1 LEADING ZERO + 3 CHANNEL IDENTIFIER BITS + CONVERSION RESULT DATA INTO CONTROL REGISTER/ SHADOW REGISTER NOTES 1. CONTROL REGISTER DATA IS LOADED ON FIRST 12 SCLK CYCLES. 2. SHADOW REGISTER DATA IS LOADED ON FIRST 16 SCLK CYCLES. CS Figure 21. Normal Mode Operation FULL SHUTDOWN (PM1 = 1, PM0 = 0) In this mode, all internal circuitry on the AD7927 is powered down. The part retains information in the control register during full shutdown. The AD7927 remains in full shutdown until the power management bits, PM1 and PM0, in the control register are changed. If a write to the control register occurs while the part is in full shutdown, with the power management bits changed to PM0 = CS rising edge. The track-and-hold that was in hold while the part was in full shutdown returns to track on the 14th SCLK falling edge. A full 16-SCLK transfer must occur to ensure the control register contents are updated; however, the DOUT line is not driven during this wake-up transfer. To ensure that the part is fully powered up, tPOWER UP should have elapsed before the next CS falling edge; otherwise, invalid data is read if a conversion is initiated before this time. Figure 22 shows the general diagram for this sequence. SCLK DOUT DIN 1 1 CHANNEL IDENTIFIER BITS + CONVERSION RESULT PART BEGINSTO POWER UP ON CS RISING EDGE AS PM1 = PM0 = 1 THE PART IS FULLY POWERED UP ONCE tPOWER UP HAS ELAPSED t12 14 16 14 16 DATA INTO CONTROL REGISTER/SHADOW REGISTER TO KEEP THE PART IN NORMAL MODE, LOAD PM1 = PM0 = 1 IN CONTROL REGISTER DATA INTO CONTROL REGISTER CONTROL REGISTER IS LOADED ON THE FIRST 12 CLOCKS. PM1 = 1, PM0 = 1 PART IS IN FULL SHUTDOWN CS Figure 22. Full Shutdown Mode Operation |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |