| Electronic Components Datasheet Search |
|
SA9605ASAR Datasheet(PDF) 6 Page - Sames |
|
|
|||||||||||||||||||||||||||||
SA9605ASAR Datasheet(HTML) 6 Page - Sames |
|
6 / 11 page ![]() SPEC-3118 (REV. 3) 6/11 29-09-2017 SA9605A OUTPUT SIGNALS Pulse and Direction Output (FOUT1, DIR) Waveforms displaying the FOUT1 and DIR signal information for each of the three phases are shown in Figure 5. Figure 5: FOUT1 and DIR waveforms These waveforms demonstrate how to establish the direction of energy flow as well as the phase from which the energy is measured. The direction of energy is indicated on the DIR pin, it is high for positive energy flow and low for negative energy flow. The state of DIR is valid for the entire low period of the FOUT1 pulse. The phase to which the pulse on the FOUT1 pin refers to, can be ascertained by counting the number of falling edges on the DIR pin prior to the falling edge of the FOUT1 pulse. The output on FOUT1 is a pulse density signal representing the instantaneous power/energy measurement. The pulse width (tp) is 71μs. The output frequency may be calculated using the following formula: ���� = 12946 × |��������1 × ��������1| + |��������2 × ��������2| + |��������3 × ��������3| 3 × �������� 2 × �������������������������������� 3.5795 where IIX is the input current on the current sense inputs on the respective channel in RMS (16μA at rated conditions), IVX is the input current on the voltage sense input on the respective channel in RMS (14 μA at rated conditions), IR is the reference current on VREF, typically 50μA, and fCRYSTAL is the frequency of the crystal used in MHz. Pulse Output (FOUT2) Although FOUT1 has a fixed frequency output, the table below shows the various frequencies selectable for different rated conditions on FOUT2. Table 1: User selectable FOUT2 frequency PGM1 PGM0 Divider FOUT2 Frequency (Hz) VSS VSS 227 5.110 VSS VDD 303 3.833 VDD VSS 454 2.555 The frequencies shown in the above table were chosen to allow a 4 - 3 - 2 scaling ratio for rated conditions. This facility provides ease of interface with applications which use the same post divider with mechanical counter or unchanged microcontroller software for different current rated kWh meters. For example, a meter manufacturer may wish to build meters for 3 system configurations with rated current loading of 80A, 60A and 40A. The only changes which have to be implemented to interface the device to different rated systems are to change the current sense resistors and select the required PGM0 and PGM1. No change to the post divider or microcontroller software is required if the FOUT2 pin is used. OSCILLATOR The SA9605A contains a crystal oscillator driver circuit requiring only an external crystal to be connected between OSC1 and OSC2. All other components are integrated on the device. The recommended crystal is a TV colour burst crystal (3.5795MHz). FOUT1 DIR Phase 1 Positive FOUT1 DIR Phase 1 Negative FOUT1 DIR Phase 2 Positive FOUT1 DIR Phase 2 Negative FOUT1 DIR Phase 3 Positive FOUT1 DIR Phase 3 Negative 71µs 8.9µs |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |