| Electronic Components Datasheet Search |
|
LTC6409 Datasheet(PDF) 16 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTC6409 Datasheet(HTML) 16 Page - Analog Devices |
|
16 / 24 page ![]() LTC6409 16 6409fb For more information www.linear.com/LTC6409 APPLICATIONS INFORMATION resistive divider between the RL • 4 = 200Ω differential resistance seen at location B and the 200Ω formed by the two 100Ω matching resistors at the LTC6409 output. Thus, the differential power at location B is 10 – 6 = 4dBm. Since the transformer ratio is 4:1 and it has an insertion loss of about 1dB, the power at location C (across RL) is calculated to be 4 – 6 – 1 = –3dBm. This means that IMD3 should be measured while the power at the output of the demo board is –3dBm which is equivalent to having 2VP-P differential peak (or 10dBm) at the output of the LTC6409. GBW vs f–3dB Gain-bandwidth product (GBW) and –3dB frequency (f–3dB) have been both specified in the Electrical Characteristics table as two different metrics for the speed of the LTC6409. GBW is obtained by measuring the gain of the amplifier at a specific frequency (fTEST) and cal- culate gain • fTEST. To measure gain, the feedback factor (i.e. b = RI/(RI + RF)) is chosen sufficiently small so that the feedback loop does not limit the available gain of the LTC6409 at fTEST, ensuring that the measured gain is the open loop gain of the amplifier. As long as this condition is met, GBW is a parameter that depends only on the internal design and compensation of the amplifier and is a suitable metric to specify the inherent speed capability of the amplifier. f–3dB, on the other hand, is a parameter of more practi- cal interest in different applications and is by definition the frequency at which the gain is 3dB lower than its low frequency value. The value of f–3dB depends on the speed of the amplifier as well as the feedback factor. Since the LTC6409 is designed to be stable in a differential signal gain of 1 (where RI = RF or b = 1/2), the maximum f–3dB is obtained and measured in this gain setting, as reported in the Electrical Characteristics table. In most amplifiers, the open loop gain response exhibits a conventional single-pole roll-off for most of the frequen- cies before crossover frequency and the GBW and f–3dB numbers are close to each other. However, the LTC6409 is intentionally compensated in such a way that its GBW is significantly larger than its f–3dB. This means that at lower frequencies (where the input signal frequencies typically lie, e.g. 100MHz) the amplifier’s gain and thus the feedback loop gain is larger. This has the important advantage of further linearizing the amplifier and improv- ing distortion at those frequencies. Looking at the Frequency Response vs Closed Loop Gain graph in the Typical Performance Characteristics section of this data sheet, one sees that for a closed loop gain (AV) of 1 (where RI = RF = 150Ω), f–3dB is about 2GHz. However, for AV = 400 (where RI = 25Ω and RF = 10kΩ), the gain at 100MHz is close to 40dB = 100V/V, implying a GBW value of 10GHz. Feedback Capacitors When the LTC6409 is configured in low differential gains, it is often advantageous to utilize a feedback capacitor (CF) in parallel with each feedback resistor (RF). The use of CF implements a pole-zero pair (in which the zero frequency is usually smaller than the pole frequency) and adds posi- tive phase to the feedback loop gain around the amplifier. Therefore, if properly chosen, the addition of CF boosts the phase margin and improves the stability response of the feedback loop. For example, with RI = RF = 150Ω, it is recommended for most general applications to use CF = 1.3pF across each RF. This value has been selected to maximize f–3dB for the LTC6409 while keeping the peaking of the closed loop gain versus frequency response under a reasonable level (<1dB). It also results in the highest frequency for 0.1dB gain flatness (f0.1dB). However, other values of CF can also be utilized and tailored to other specific applications. In general, a larger value for CF reduces the peaking (overshoot) of the amplifier in both frequency and time domains, but also decreases the closed loop bandwidth (f–3dB). For example, while for a closed loop gain (AV) of 5, CF = 0.8pF results in maximum f–3dB (as previously shown in the Frequency Response vs Closed Loop Gain graph of this data sheet), if CF = 1.2pF is used, the amplifier exhibits no overshoot in the time domain which is desirable in certain applications. Both the circuits discussed in this section have been shown in the Typical Applications section of this data sheet. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |