Back Button LTM4675 Datasheet HTML 60Page - Linear Technology LTM4675 Datasheet HTML 61Page - Linear Technology LTM4675 Datasheet HTML 62Page - Linear Technology LTM4675 Datasheet HTML 63Page - Linear Technology LTM4675 Datasheet HTML 64Page - Linear Technology LTM4675 Datasheet HTML 65Page - Linear Technology LTM4675 Datasheet HTML 66Page - Linear Technology LTM4675 Datasheet HTML 67Page - Linear Technology LTM4675 Datasheet HTML 68Page - Linear Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 64 / 136 page
background image
LTM4676A
64
4676afa
For more information www.linear.com/LTM4676A
applicaTions inForMaTion
PMBus COMMUNICATION AND COMMAND
PROCESSING
The LTM4676A has one deep buffer to hold the last data
written for each supported command prior to processing
as shown in Figure 8; Write Command Data Processing.
When the part receives a new command from the bus,
it copies the data into the Write Command Data Buffer,
indicates to the internal processor that this command
data needs to be fetched, and converts the command to
its internal format so that it can be executed.
Two distinct parallel blocks manage command buffering
and command processing (fetch, convert, and execute)
to ensure the last data written to any command is never
lost. Command data buffering handles incoming PM-
Bus writes by storing the command data to the Write
Command Data Buffer and marking these commands for
future processing. The internal processor runs in parallel
and handles the sometimes slower task of fetching, con-
vertingandexecutingcommandsmarkedforprocessing.
Some computationally intensive commands (e.g., timing
parameters, temperatures, voltages and currents) have
internal processor execution times that may be long
relative to PMBus timing. If the part is busy processing a
command, and new command(s) arrive, execution may
be delayed or processed in a different order than received.
Thepartindicateswheninternalcalculationsareinprocess
via bit 5 of MFR_COMMON (‘calculations not pending’).
When the part is busy calculating, bit 5 is cleared. When
this bit is set, the part is ready for another command. An
example polling loop is provided in Figure 8 which ensures
that commands are processed in order while simplifying
error handling routines.
When the part receives a new command while it is busy,
it will communicate this condition using standard PMBus
protocol. Depending on part configuration it may either
NACK the command or return all ones (0xFF) for reads. It
may also generate a BUSY fault and ALERT notification,
or stretch the SCL clock low. For more information refer
to PMBus Specification v1.2, Part II, Section 10.8.7 and
SMBusv2.0section4.3.3.Clockstretchingcanbeenabled
by asserting bit 1 of MFR_CONFIG_ALL. Clock stretching
will only occur if enabled and the bus communication
speed exceeds 100kHz.
PMBus busy protocols are well accepted standards, but
can make writing system level software somewhat com-
plex. The part provides three ‘hand shaking’ status bits
which reduce complexity while enabling robust system
level communication.
The three hand shaking status bits are in the MFR_
COMMON register. When the part is busy executing an
internal operation, it will clear bit 6 of MFR_COMMON
(‘module not busy’). When the part is busy specifically
because it is in a transitional VOUT state (margining hi/lo,
power off/on, moving to a new output voltage set point,
etc.) it will clear bit 4 of MFR_COMMON (‘output not in
transition’). When internal calculations are in process, the
part will clear bit 5 of MFR_COMMON (‘calculations not
pending’). These three status bits can be polled with a
PMBus read byte of the MFR_COMMON register until all
three bits are set. A command immediately following the
status bits being set will be accepted without NACKing or
generating a BUSY fault/ALERT notification. The part can
NACK commands for other reasons, however, as required
by the PMBus spec (for instance, an invalid command or
data). An example of a robust command write algorithm
fortheVOUT_COMMANDnregisterisprovidedinFigure 9.
DECODER
CMD
INTERNAL
PROCESSOR
WRITE COMMAND
DATA BUFFER
PAGE
CMDS
0x00
0x21
0xFD
4676A F08
x1
•
•
•
•
•
•
MFR_RESET
VOUT_COMMAND
S
CALCULATIONS
PENDING
PMBus
WRITE
R
FETCH,
CONVERT
DATA
AND
EXECUTE
DATA
MUX
Figure 8. Write Command Data Processing
Figure 9. Example of a Command Write of VOUT_COMMAND
// wait until bits 6, 5, and 4 of MFR_COMMON are all set
do
{
mfrCommonValue = PMBUS_READ_BYTE(0xEF);
partReady = (mfrCommonValue & 0x68) == 0x68;
}while(!partReady)
// now the part is ready to receive the next command
PMBUS_WRITE_WORD(0x21, 0x2000); //write VOUT_COMMAND to 2V



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com