| Electronic Components Datasheet Search |
|
PCT2202 Datasheet(PDF) 9 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCT2202 Datasheet(HTML) 9 Page - NXP Semiconductors |
|
9 / 30 page ![]() PCT2202 All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2015. All rights reserved. Product data sheet Rev. 1.1 — 14 August 2015 9 of 30 NXP Semiconductors PCT2202 Ultra low power, 1.8 V, 1 deg. C accuracy, I2C-bus digital temp sensor The AL bit will continue to read as ‘0’ until the temperature falls below TLOW for the programmed number of consecutive faults, when it will again read as ‘1’. The status of the TM bit does not affect the status of the AL bit. 7.3.3 CR1, CR0 - Conversion rate bits The conversion rate bits, CR1 and CR0, configure the PCT2202 for conversion rates of 8 Hz, 4 Hz, 1 Hz or 0.25 Hz. The default rate is 4 Hz. The PCT2202 has a typical conversion time of 26 ms. To achieve different conversion rates, the PCT2202 makes a conversion and after that powers down and waits for the appropriate delay set by CR1 and CR0. Table 11 shows the settings for CR1 and CR0. After power-up or general-call reset, the PCT2202 immediately starts a conversion, as shown in Figure 5. The first result is available after 26 ms (typical). The active quiescent current during conversion is 40 A (typical at +27 C). The quiescent current during delay is 2.2 A (typical at +27 C). 7.3.4 SD - Shut-down mode bit The Shut-down mode bit saves maximum power by shutting down all device circuitry other than the serial interface, reducing current consumption to typically less than 0.5 A. Shut-down mode is enabled when the SD bit is ‘1’. The device shuts down when current conversion is completed. When SD is equal to ‘0’, the device maintains a continuous conversion state. 7.3.5 TM - Thermostat mode bit The Thermostat mode bit indicates to the device whether to operate in Comparator mode (TM = 0) or Interrupt mode (TM = 1). For more information on comparator and interrupt modes, see Section 7.4 “High-limit and low-limit registers”. Table 11. Conversion rate settings CR1 CR0 Conversion rate 0 0 0.25 Hz 01 1 Hz 1 0 4 Hz (default) 11 8 Hz (1) Delay is set by CR1 and CR0. Fig 5. Conversion start 002aag847 26 ms 26 ms delay(1) start-up start of conversion |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |