Electronic Components Datasheet Search
  English  ▼

X  

BMP180 Datasheet(PDF) 20 Page - Bosch Sensortec GmbH

Part # BMP180
Description  Digital pressure sensor
PDF  29 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  BOSCH [Bosch Sensortec GmbH]
Direct Link  https://www.bosch-sensortec.com
Logo BOSCH - Bosch Sensortec GmbH

BMP180 Datasheet(HTML) 20 Page - Bosch Sensortec GmbH

Back Button BMP180 Datasheet HTML 16Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 17Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 18Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 19Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 20Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 21Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 22Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 23Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 24Page - Bosch Sensortec GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 20 / 29 page
background image
Data sheet
BMP180
Page 20
BST-BMP180-DS000-12 | Revision 2.8 | May 2015
Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third
parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
5.2 Device and register address
The BMP180 module address is shown below. The LSB of the device address distinguishes
between read (1) and write (0) operation, corresponding to address 0xEF (read) and 0xEE (write).
Table 7: BMP180 addresses
A7
A6
A5
A4
A3
A2
A1
W/R
1
1
1
0
1
1
1
0/1
5.3 I2C protocol
The I2C interface protocol has special bus signal conditions. Start (S), stop (P) and binary data
conditions are shown below. At start condition, SCL is high and SDA has a falling edge. Then the
slave address is sent. After the 7 address bits, the direction control bit R/W selects the read or write
operation. When a slave device recognizes that it is being addressed, it should acknowledge by
pulling SDA low in the ninth SCL (ACK) cycle.
At stop condition, SCL is also high, but SDA has a rising edge. Data must be held stable at SDA
when SCL is high. Data can change value at SDA only when SCL is low.
Even though VDDIO can be powered on before VDD, there is a chance of excessive power
consumption (a few mA) if this sequence is used, and the state of the output pins is undefined so
that the bus can be locked. Therefore, VDD must be powered before VDDIO unless the limitations
above are understood and not critical.
Figure 7: I2C protocol



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com