16 / 20 page ![]() REV. 0 ADF4212L –16– PROGRAM MODES Table III and Table V show how to set up the Program Modes in the ADF4212L. The following should be noted: 1. IF and RF Analog Lock Detect indicate when the PLL is in lock. When the loop is locked and either IF or RF Analog Lock Detect is selected, then the MUXOUT pin will show a logic high with narrow low going pulses. When the IF/RF Analog Lock Detect is chosen, then the locked condition is indicated only when both IF and RF loops are locked. 2. The IF Counter Reset Mode resets the R and AB counters in the IF section and also puts the IF charge pump into three- state. The RF Counter Reset Mode resets the R and AB counters in the RF section and also puts the RF charge pump into three-state. The IF and RF Counter Reset Mode does both of the above. Upon removal of the reset bits, the AB counter resumes counting in close alignment with the R counter. (Maximum error is one prescaler output cycle.) 3. The Fastlock Mode uses MUXOUT to switch a second loop filter damping resistor to ground during Fastlock operation. Activation of Fastlock occurs whenever RF CP Gain in the RF Reference counter is set to “1.” IF Power-Down It is possible to program the ADF4210 family for either synchro- nous or asynchronous power-down on either the IF or RF side. Synchronous IF Power-Down Programming a “1” to P7 of the ADF4212L will initiate a power- down. If P2 of the ADF4212L has been set to “0” (normal operation), a synchronous power-down is conducted. The device will automatically put the charge pump into three-state and com- plete the power-down. Asynchronous IF Power-Down If P2 of the ADF4212L has been set to “1” (three-state the IF charge pump) and P7 is subsequently set to “1,” an asynchronous power-down is conducted. The device will go into power-down on the rising edge of LE, which latches the “1” to the IF Power- Down Bit (P7). Synchronous RF Power-Down Programming a “1” to P16 of the ADF4212L will initiate a power-down. If P10 of the ADF4212L has been set to “0” (normal operation), a synchronous power-down is conducted. The device will automatically put the charge pump into three- state and then complete the power-down. Asynchronous RF Power-Down If P10 of the ADF4212L has been set to “1” (three-state the RF charge pump) and P16 is subsequently set to “1,” an asynchronous power-down is conducted. The device will go into power-down on the rising edge of LE, which latches the “1” to the RF Power- Down Bit (P16). Activation of either synchronous or asynchronous power-down forces the IF/RF loop’s R and AB dividers to their load state conditions and the IF/RF input section is debiased to a high impedance state. The REFIN oscillator circuit is only disabled if both the IF and RF power-downs are set. The input register and latches remain active and are capable of loading and latching data during all power-down modes. The IF/RF section of the devices will return to normal powered-up operation immediately upon LE latching a “0” to the appropriate Power-Down Bit. IF SECTION PROGRAMMABLE IF REFERENCE (R) COUNTER If control bits C2, C1 are 0, 0, the data is transferred from the input shift register to the 14-bit IFR counter. Table III shows the input shift register data format for the IFR counter and the divide ratios possible. IF Phase Detector Polarity P1 sets the IF Phase Detector Polarity. When the IF VCO char- acteristics are positive, this should be set to “1.” When they are negative, it should be set to “0.” See Table III. IF Charge Pump Three-State P2 puts the IF charge pump into three-state mode when pro- grammed to a “1.” It should be set to “0” for normal operation. See Table III. IF PROGRAM MODES Table III and Table V show how to set up the Program Modes in the ADF4212L. IF Charge Pump Currents IFCP2, IFCP1, IFCP0 program Current Setting for the IF charge pump. See Table III. PROGRAMMABLE IF AB COUNTER If control bits C2, C1 are 0, 1, the data in the input register is used to program the IF AB counter. The N counter consists of a 6-bit swallow counter (A counter) and 12-bit programmable counter (B counter). Table IV shows the input register data format for pro- gramming the IF AB counter and the divide ratios possible. IF Prescaler Value P5 and P6 in the IF A, B Counter Latch set the IF prescaler values. See Table IV. IF Power-Down Table III and Table V show the power-down bits in the ADF4212L. IF Fastlock The IF CP Gain Bit (P8) of the IF N Register in the ADF4212L is the Fastlock Enable Bit. Only when this is “1” is IF Fastlock enabled. When Fastlock is enabled, the IF CP current is set to maximum value. Also an extra loop filter damping resistor to ground is switched in using the FLO pin, thus compensating for the change in loop characteristics while in Fastlock. Since the IF CP Gain Bit is contained in the IF N Counter, only one write is needed to both program a new output frequency and initiate Fast- lock. To come out of fastlock, the IF CP Gain bit on the IF N Register must be set to “0.” See Table IV. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |