Back Button DS2152 Datasheet HTML 32Page - Maxim Integrated Products DS2152 Datasheet HTML 33Page - Maxim Integrated Products DS2152 Datasheet HTML 34Page - Maxim Integrated Products DS2152 Datasheet HTML 35Page - Maxim Integrated Products DS2152 Datasheet HTML 36Page - Maxim Integrated Products DS2152 Datasheet HTML 37Page - Maxim Integrated Products DS2152 Datasheet HTML 38Page - Maxim Integrated Products DS2152 Datasheet HTML 39Page - Maxim Integrated Products DS2152 Datasheet HTML 40Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 36 / 97 page
background image
DS2152
36 of 97
Table 5-2. Alarm Criteria
ALARM
SET CRITERIA
CLEAR CRITERIA
Blue Alarm (AIS)
(See note 1 below)
When over a 3ms window, five or
less 0s are received
When over a 3ms window, six or
more 0s are received
Yellow Alarm (RAI)
1. D4 bit 2 mode(RCR2.2 = 0)
2. D4 12th F-bit mode
(RCR2.2=1; this mode is also
referred to as the "Japanese
Yellow Alarm"
3. ESF mode
When bit 2 of 256 consecutive
channels is set to 0 for at least 254
occurrences
When the 12th framing bit is set to
1 for two consecutive occurrences
When 16 consecutive patterns of
00FF appear in the FDL
When bit 2 of 256 consecutive
channels is set to 0 for less than 254
occurrences
When the 12th framing bit is set to 0
for two consecutive occurrences
When 14 or less patterns of 00FF
hex out of 16 possible appear in the
FDL
Red Alarm (LRCL)
(This alarm is also referred to as
Loss Of Signal)
When 192 consecutive 0s are
received
When 14 or more 1s out of 112
possible bit positions are received
starting with the first one received
Note 1: The definition of Blue Alarm (or Alarm Indication Signal) is an unframed all 1s signal. Blue alarm detectors should be able to
operate properly in the presence of a 10-3 error rate and they should not falsely trigger on a framed all 1s signal. The blue alarm criteria in
the DS2152 have been set to achieve this performance. It is recommended that the RBL bit be qualified with the RLOS bit.
Note 2: ANSI specifications use a different nomenclature than the DS2152 does; the following terms are equivalent:
RBL = AIS
LRCL = LOS
RLOS = LOF
RYEL = RAI



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com