Back Button MSM7654 Datasheet HTML 19Page - OKI electronic componets MSM7654 Datasheet HTML 20Page - OKI electronic componets MSM7654 Datasheet HTML 21Page - OKI electronic componets MSM7654 Datasheet HTML 22Page - OKI electronic componets MSM7654 Datasheet HTML 23Page - OKI electronic componets MSM7654 Datasheet HTML 24Page - OKI electronic componets MSM7654 Datasheet HTML 25Page - OKI electronic componets MSM7654 Datasheet HTML 26Page - OKI electronic componets MSM7654 Datasheet HTML 27Page - OKI electronic componets Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 53 page
background image
¡ Semiconductor
MSM7654
23/52
The normal vertical blanking periods cannot be obtained in the following cases:
(1) If the HSYNC_L peiod is longer than the standard, the vertical blanking period is output in
the HSYNC_L period unless the pixel counter overflows in one line.
However, in the waveform the front porch period becomes longer.
VSYNC_L
HSYNC_L (normal)
HSYNC_L (Long)
Composite (Output)
The front porch period is longer
than when the normal HSYNC_L
signal is input.
Front Porch
When the pixel counter overflows, the encoder recognizes that the HSYNC_L signal has been
input when the pixel counter becomes zero and the next line starts.
The following HSYNC_L signal resets the pixel counter again.
Therefore, inputting such a signal not only disturbs signals in the vertical blanking period but
also causes abnormal operations in the horizontal period.
(2) If the HSYNC_L period is shorter than the standard, serrations may be lost.
(3) If the VSYNC_L period is longer than the standard, the vertical blanking period is output as
shown below.
• If the number of lines is greater than the standard value, the first equalizing pulse period is
longer.
• If the number of lines is equal to the standard value, the contents of output signals per line
are normal.
• If the number of lines is smaller than the standard value, the first equalizing pulse period is
shorter.
(4) If the VSYNC_L period is shorter than the standard, the vertical blanking period is output as
shown below.
• If the number of lines is greater than the standard value, the first equalizing pulse period is
longer.
• If the number of lines is equal to the standard value, the contents of output signals per line
are normal.
• If the number of lines is smaller than the standard value, the first equalizing pulse period is
shorter.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com