Back Button TP-UART Datasheet HTML 12Page - Siemens Semiconductor Group TP-UART Datasheet HTML 13Page - Siemens Semiconductor Group TP-UART Datasheet HTML 14Page - Siemens Semiconductor Group TP-UART Datasheet HTML 15Page - Siemens Semiconductor Group TP-UART Datasheet HTML 16Page - Siemens Semiconductor Group TP-UART Datasheet HTML 17Page - Siemens Semiconductor Group TP-UART Datasheet HTML 18Page - Siemens Semiconductor Group TP-UART Datasheet HTML 19Page - Siemens Semiconductor Group TP-UART Datasheet HTML 20Page - Siemens Semiconductor Group Next Button
Zoom Inzoom in Zoom Outzoom out
 16 / 26 page
background image
TP-UART-IC
The reproduction, transmission or use of this document or it‘s contents is not permitted without express written authority. All
rights, including right created by patent grant or registration of a utility model or design, are reserved. Technical changes
reserved.
25.15.10.41.33a
25.10.01
page
16
FF = Frame Format
10 Standard Length L_DATA-EIB-Frame
00 Long L_DATA-Frames
11 Polling Frame
R = Repeat-flag (on the EIB 1 = not repeated, 0 = repeated)
1 = repeat the telegram on the EIB 3 times
send first time with repeat flag = 1 and repeat with repeat flag = 0
0 = don’t repeat the telegram on the EIB; send only once with repeat flag = 1
CC = Class:
control field
FFR1 cc00
data link frame type
class
repeat flag
(0 = repeated)
FFR1 0000
L_DATA request
system
set by TP-UART-IC
FFR1 1000
L_DATA request
alarm
set by TP-UART-IC
FFR1 0100
L_DATA request
high
set by TP-UART-IC
FFR1 1100
L_DATA request
normal
set by TP-UART-IC
1111 0000
L_POLLDATA request
system priority
= 1
3.2.3.1.5.2U_L_DataContinue-Service
The U_L_DataContinue-Service transmits one byte containing an EIB-L_Data-Frame to the
TP-UART-IC. The index starts with 1 and the maximum value is 62 depending on the length
of the frame. But the EIB confirms just the length of 22 Bytes.
UART-Control Field
Additional Information
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
1
0
i
i
i
i
i
i
d
d
d
d
d
d
d
d
L-Data
Index
EIB-Data Byte for L-Data-Frame
3.2.3.1.5.3U_L_DataEnd-Service
The U_L_DataEnd-Service marks the end of the transmission of the EIB frame. After
receiving this service the TP - UART controls the checksum and in case of correctness it
starts the transmission on the EIB, else the UART returns a state indication with receive-
error flag is set.
UART-Control Field(40hex)
Additional Information
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
0
1
l
l
l
l
l
l
c
c
c
c
c
c
c
c
L-Data
last index + 1
Checksum



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com