| Electronic Components Datasheet Search |
|
MP7758GF Datasheet(PDF) 16 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP7758GF Datasheet(HTML) 16 Page - Monolithic Power Systems |
|
16 / 22 page ![]() MP7758 – 18V, 2x15W, STEREO BTL, INDUCTORLESS CLASS-D AUDIO AMPLIFIER MP7758 Rev. 1.0 www.MonolithicPower.com 16 12/3/2020 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. Gain Setting The MP7758 ’s gain is set by the input terminals GAIN0 and GAIN1. The actual gain settings are controlled by the ratios of the internal input and feedback resistors (see Table 2). Table 2: Gain Setting GAIN0 GAIN1 Typical Gain (dB) Typical Input Impedance (k Ω) 0 0 20 75 1 0 26 50 0 1 32 30 1 1 36 20 Over-Temperature Shutdown The MP7758 monitors the temperature. If the die temperature rises above 150°C, all switches turn off. The temperature must fall below 130°C before normal operation resumes. The device uses the same start-up sequence to prevent popping noise. Short-Circuit Protection (SCP) The MP7758 has internal overload and short- circuit protection (SCP). The currents in both the high-side and low-side MOSFETs are measured. If a short circuit is detected, all MOSFETs of the full bride that detected the over-current condition go into high impedance for a fixed duration before resuming normal operation. If the short circuit condition is removed after the fixed duration, the MP7758 restarts. The device uses the same start-up sequence to prevent popping noise. Fault Output The MP7758 includes an open drain, active low fault indicator output on the /FAULT pin. A fault triggers if either the current limit or thermal shutdown threshold is tripped. A fault on any channel causes the /FAULT pin to pull low. A fault on either channel causes the all outputs to go into high impedance. When the fault condition is removed, the MP7758 resumes normal operation (see Figure 5). Normal Operation Over-current condition detected? No Disable output, /FAULT = low Yes Enable output, /FAULT = high Yes TEMP > 150°C? No Disable output, /FAULT = low Yes TEMP < 130°C? No Yes Enable output, /FAULT = high 100µs timeout finished? No Figure 5: Fault Timing Chart |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |