Back Button LM57 Datasheet HTML 22Page - Texas Instruments LM57 Datasheet HTML 23Page - Texas Instruments LM57 Datasheet HTML 24Page - Texas Instruments LM57 Datasheet HTML 25Page - Texas Instruments LM57 Datasheet HTML 26Page - Texas Instruments LM57 Datasheet HTML 27Page - Texas Instruments LM57 Datasheet HTML 28Page - Texas Instruments LM57 Datasheet HTML 29Page - Texas Instruments LM57 Datasheet HTML 30Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 26 / 39 page
background image
VDD Supply
(+2.4V to +5.5V)
GND
VDD
TOVER
VTEMP
TRIP TEST
Microcontroller
LM57
ADC Input
TOVER
Digital In
Digital Out
SENSE1
SENSE2
Analog
+2.4V to +5.5V
VTEMP
VDD
CBP
RIN
Input
Pin
CFILTER
LM57
CSAMPLE
Reset
Sample
GND
SAR Analog-to-Digital Converter
CPIN
LM57-Q1
SNIS191A – JULY 2015 – REVISED JULY 2015
www.ti.com
8 Application and Implementation
NOTE
Information in the following applications sections is not part of the TI component
specification, and TI does not warrant its accuracy or completeness. TI’s customers are
responsible for determining suitability of components for their purposes. Customers should
validate and test their design implementation to confirm system functionality.
8.1 Application Information
The LM57-Q1 has several outputs allowing for varying system implementations.
8.1.1 ADC Input Considerations
The LM57-Q1 has an analog temperature sensor output (VTEMP) that can be directly connected to an ADC
(Analog to Digital Converter) input. Most CMOS ADCs found in microcontrollers and ASICs have a sampled data
comparator input structure. When the ADC charges the sampling cap, it requires instantaneous charge from the
output of the analog source such as the LM57-Q1 temperature sensor and many op amps. This requirement is
easily accommodated by the addition of a capacitor (CFILTER). The size of CFILTER depends on the size of the
sampling capacitor and the sampling frequency. Because not all ADCs have identical input stages, the charge
requirements will vary. The general ADC application shown in Figure 20 is an example only.
Figure 20. Suggested Connection to a Sampling Analog-to-Digital Converter Input Stage
8.2 Typical Application
Figure 21. Typical Application Schematic with Microcontroller TRIP TEST Control
26
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Product Folder Links: LM57-Q1



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com