  MS5541B Datasheet HTML 1Page - Intersema Sensoric SA MS5541B Datasheet HTML 2Page - Intersema Sensoric SA MS5541B Datasheet HTML 3Page - Intersema Sensoric SA MS5541B Datasheet HTML 4Page - Intersema Sensoric SA MS5541B Datasheet HTML 5Page - Intersema Sensoric SA MS5541B Datasheet HTML 6Page - Intersema Sensoric SA MS5541B Datasheet HTML 7Page - Intersema Sensoric SA MS5541B Datasheet HTML 8Page - Intersema Sensoric SA MS5541B Datasheet HTML 9Page - Intersema Sensoric SA Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 18 page
background image
DA5541B_005.doc
September 25th, 2006
5
00005541766 ECN865
PRESSURE OUTPUT CHARACTERISTICS
With the calibration data provided by the MS5541B (stored in the interface IC) the following characteristics can
be achieved:
Parameter
Conditions
Min
Typ
Max
Unit
Note
Resolution
1.2
mbar
1
Absolute Pressure Accuracy
p = 0 .. 5bar
p = 0 .. 10bar
p = 0 .. 14bar
Ta = 0 .. 40°C
-25
-60
-150
+20
+20
+20
mbar
mbar
mbar
2
p = 0 .. 5bar
p = 0 .. 10bar
p = 0 .. 14bar
Ta = -40 .. 85°C
-40
-60
-160
+100
+180
+200
mbar
mbar
mbar
3
Error over Temperature
Ta = -40…+85°C
p = const. Relative to 20°C
-10
+100
mbar
Long-term Stability
6 month
20
mbar
4
Maximum Error over Supply
Voltage
VDD = 2.2…3.6V
-20
20
mbar/V
NOTES
1) A stable pressure reading of the given resolution requires taking the average of 2 to 4 subsequent pressure
values due to noise of the ADC.
2) Maximum error of pressure reading over the pressure range.
3) With the second-order temperature compensation as described in Section “FUNCTION". See next section
for typical operating curves.
4) The long-term stability is measured with non-soldered devices
TEMPERATURE OUTPUT CHARACTERISTICS
This temperature information is not required for most applications, but it is necessary to allow for temperature
compensation of the pressure output. The reference temperature is 20°C.
Parameter
Conditions
Min
Typ
Max
Unit
Note
Resolution
0.005
0.01
0.015
°C
Accuracy
Ta = 20°C
-0.8
0.8
°C
Ta = -40…+85°C
± 2
°C
1
Maximum Error over Supply
Voltage
VDD = 2.2…3.6V
-0.3
0.3
°C/V
NOTE
1) With the second-order temperature compensation as described in Section “FUNCTION". See next section
for typical operating curves.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com