Electronic Components Datasheet Search
  English  ▼

X  

MS5541B Datasheet(PDF) 11 Page - Intersema Sensoric SA

Part # MS5541B
Description  MINIATURE 14 bar MODULE
PDF  18 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  INTERSEMA [Intersema Sensoric SA]
Direct Link  http://www.meas-spec.com/
Logo INTERSEMA - Intersema Sensoric SA

MS5541B Datasheet(HTML) 11 Page - Intersema Sensoric SA

Back Button MS5541B Datasheet HTML 7Page - Intersema Sensoric SA MS5541B Datasheet HTML 8Page - Intersema Sensoric SA MS5541B Datasheet HTML 9Page - Intersema Sensoric SA MS5541B Datasheet HTML 10Page - Intersema Sensoric SA MS5541B Datasheet HTML 11Page - Intersema Sensoric SA MS5541B Datasheet HTML 12Page - Intersema Sensoric SA MS5541B Datasheet HTML 13Page - Intersema Sensoric SA MS5541B Datasheet HTML 14Page - Intersema Sensoric SA MS5541B Datasheet HTML 15Page - Intersema Sensoric SA Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 18 page
background image
DA5541B_005.doc
September 25th, 2006
11
00005541766 ECN865
C1 (13 Bit)
C2/I (3 Bit)
Word 1
DB12
DB11
DB10
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
DB12
DB11
DB10
C2/II (10 Bit)
C5/I (6 Bit)
Word 2
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
DB11
DB10
DB9
DB8
DB7
DB6
C3 (10 Bit)
C5/II (6 Bit)
Word 3
DB9
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
DB5
DB4
DB3
DB2
DB1
DB0
C4 (9 Bit)
C6 (7-Bit)
Word 4
DB8
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB1
DB6
DB5
DB4
DB3
DB2
DB1
DB0
Fig. 4: Arrangement (Bit-pattern) of calibration data in Word1 to Word4.
SECOND-ORDER TEMPERATURE COMPENSATION
In order to obtain full temperature accuracy over the whole temperature range, it is recommended to
compensate for the non-linearity of the output of the temperature sensor. This can be achieved by the second
order temperature calculation, i.e. by replacing the “TEMP” equation given in fig. 1 by the small algorithm given
hereafter. The calculation of the temperature compensated pressure as shown in Fig. 3 is not affected by this
second-order calculation.
High Temperatures
dT2 = dT – (dT/128*dT/128)/8
dT < 0
yes
Calculate temperature
TEMP = (200 + dT2*(C6+100)/211) (0.1°C)
Low Temperatures
dT2 = dT – (dT/128*dT/128)/2
dT
≥ 0
yes
Fig. 5: Flow chart for calculating the temperature and pressure to the optimum accuracy.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com