| Electronic Components Datasheet Search |
|
TMP464 Datasheet(PDF) 26 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP464 Datasheet(HTML) 26 Page - Texas Instruments |
|
26 / 42 page ![]() 26 TMP464 SBOS835C – MAY 2017 – REVISED OCTOBER 2019 www.ti.com Product Folder Links: TMP464 Submit Documentation Feedback Copyright © 2017–2019, Texas Instruments Incorporated Table 12. η-Factor Range NADJUST ONLY BITS 15 TO 8 IN THE REGISTER ARE SHOWN η BINARY HEX DECIMAL 0111 1111 7F 127 0.950205 0000 1010 0A 10 1.003195 0000 1000 08 8 1.004153 0000 0110 06 6 1.005112 0000 0100 04 4 1.006073 0000 0010 02 2 1.007035 0000 0001 01 1 1.007517 0000 0000 00 0 1.008 1111 1111 FF –1 1.008483 1111 1110 FE –2 1.008966 1111 1100 FC –4 1.009935 1111 1010 FA –6 1.010905 1111 1000 F8 –8 1.011877 1111 0110 F6 –10 1.012851 1000 0000 80 –128 1.073829 7.6.1.9 Remote Temperature Offset Register The offset registers allow the TMP464 device to store any system offset compensation value that may result from precision calibration. The value in these registers is added to the remote temperature results upon every conversion. Each of the four temperature channels have an independent assigned offset register (addresses 40h, 48h, 50h, and 58h). Combined with the independent η-factor corrections, this function allows for very accurate system calibration over the entire temperature range for each remote channel. The format of these registers is the same as the temperature value registers with a range from +127.9375 to –128. Take care to program this register with sign extension, as values above +127.9375 and below –128 are not supported. 7.6.1.10 THERM Hysteresis Register The THERM Hysteresis register (address 38h) sets the value of the hysteresis used by the temperature comparison logic. All temperature reading comparisons have a common hysteresis. Hysteresis prevents oscillations from occurring on the THERM and THERM2 outputs as the measured temperature approaches the comparator threshold (see the THERM Functions section). The resolution of the THERM Hysteresis register is 1°C and ranges from 0°C to 255°C. 7.6.1.11 Local and Remote THERM and THERM2 Limit Registers Each of the four remote and the local temperature channels has associated independent THERM and THERM2 Limit registers. There are five THERM registers (addresses 39h, 42h, 4Ah, 52h, and 5Ah) and five THERM2 registers (addresses 39h, 43h, 4Bh, and 53h), 10 registers in total. The resolution of these registers is 0.5°C and ranges from +255.5°C to –255°C. See the THERM Functions section for more information. Setting a THERM limit to 255.5°C disables the THERM limit comparison for that particular channel and disables the limit flag from being set in the THERM Status register. This prevents the associated channel from activating the THERM output. THERM2 limits, status, and outputs function similarly. 7.6.1.12 Block Read - Auto Increment Pointer Block reads can be initiated by setting the pointer register to 80h to 84h. The temperature results are mirrored at pointer addresses 80h to 84h; temperature results for all the channels can be read with one read transaction. Setting the pointer register to any address from 80h to 84h signals to the TMP464 device that a block of more than two bytes must be transmitted before a design stop is issued. In block read mode, the TMP464 device auto increments the pointer address. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |