Back Button MLX90121 Datasheet HTML 7Page - Melexis Microelectronic Systems MLX90121 Datasheet HTML 8Page - Melexis Microelectronic Systems MLX90121 Datasheet HTML 9Page - Melexis Microelectronic Systems MLX90121 Datasheet HTML 10Page - Melexis Microelectronic Systems MLX90121 Datasheet HTML 11Page - Melexis Microelectronic Systems MLX90121 Datasheet HTML 12Page - Melexis Microelectronic Systems MLX90121 Datasheet HTML 13Page - Melexis Microelectronic Systems MLX90121 Datasheet HTML 14Page - Melexis Microelectronic Systems MLX90121 Datasheet HTML 15Page - Melexis Microelectronic Systems Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 26 page
background image
MLX90121
13.56MHz RFID Transceiver
3901090121
Page 11 of 26
Data Sheet
Rev. 007
Jan-2008
11.3.1.b. Direct Transmission
Before analog processing, data transmission can be either direct or pre-processed by means of hardware
accelerators. Direct transmission can be performed with the following setup:
Signal
Assign
MODE
RTB
DIN
CK
1
0
Data to transmit
0
OUT
DSYNC
x
x
Data has to be transmitted in real time by the microcontroller on DIN input. The modulation is done when
DIN is asserted low, so by default DIN has to be asserted high. If a configuration register has to be
written, keep DIN high when MODE is asserted low. In configuration mode, the field is held without
modulation independently of DIN.
11.3.1.c. Hardware Encoding Transmission
This programmable encoder allows predefining six different patterns of 8 bits. The encoder is selected by
setting the bit EncoderEn in the DigitalConfig register.
Symbol Setup
The six symbols are called EncoderSym0 to EncoderSym5. There is a seventh symbol which is hard-
coded to 0xFF (11111111).
A symbol is built with 8 bits as shown in the following figure.
1
0
1
1
1
1
1
0
Symbol
Code
ISO Examples
The ISO15693 protocol, mode 1 out of 4, is implemented using six symbols as shown in the following
table. Start of frame (SOF), end of frame (EOF) and pulses are all encoded using one symbol.
ISO15693 (1 out of 4)
Symbol
Name
Code
Sym0
Sym1
Sym2
Sym3
Sym4
Sym5
Pulse1
Pulse2
Pulse3
Pulse4
SOF
EOF
10111111
11101111
11111011
11111110
01111011
11011111



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com