Back Button C5000 Datasheet HTML 2Page - HAKKO Corporation C5000 Datasheet HTML 3Page - HAKKO Corporation C5000 Datasheet HTML 4Page - HAKKO Corporation C5000 Datasheet HTML 5Page - HAKKO Corporation C5000 Datasheet HTML 6Page - HAKKO Corporation C5000 Datasheet HTML 7Page - HAKKO Corporation C5000 Datasheet HTML 8Page - HAKKO Corporation C5000 Datasheet HTML 9Page - HAKKO Corporation C5000 Datasheet HTML 10Page - HAKKO Corporation  
Zoom Inzoom in Zoom Outzoom out
 6 / 10 page
background image
6. MAINTENANCE(Continued)
● Pump
Turn off the tool, remove the power plug from the power outlet and wait until the unit has
cooled completely.
1. Loosen the screws on the back of the pump cover and remove the pump cover.
2. Remove the fixing plate.
3. Clean the valve plate, fixing plate and pump head with isopropyl alcohol.
Align the notch on the pump head with the corresponding notch on the valve plate.
Match the notch on the outside of the pump head with the one on the fixing plate.
Mount the diaphragm so that it is smooth and taut.
● Replacing the heating element (heating core)
Turn off the tool, remove the power plug from the outlet and wait until the unit has cooled
completely.
1. Remove the nozzle and element cover assembly with the nozzle changing tool and remove
the joint cover.
2. Loosen the screw at the back of the pump cover and remove the pump cover.
3. Remove the 6 screws from the handpiece (including 2 screws at the flange) and carefully
separate the housing.
4. Disconnect the heating element terminal and replace the heating element.
5. Assemble using the same procedure in reverse.
6. Calibrate the nozzle temperature.
Be sure to calibrate the nozzle temperature after replacing the heating element. Failure to do
this may result in a heater temperature that is much higher or lower than the previous one,
and can contribute to accelerated oxidation and/or wear of the nozzle, or premature failure of
the heating element.
Fixing plate
Valve plate
Pump head
Diaphragm
Remove the 2 screws.
Remove the joint cover.
Flange
2 screws (Flange)
Be careful of the spring when opening
the tool to replace the heating element.
Terminal
Push



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com