Back Button ADP1877ACPZ-R7 Datasheet HTML 10Page - Analog Devices ADP1877ACPZ-R7 Datasheet HTML 11Page - Analog Devices ADP1877ACPZ-R7 Datasheet HTML 12Page - Analog Devices ADP1877ACPZ-R7 Datasheet HTML 13Page - Analog Devices ADP1877ACPZ-R7 Datasheet HTML 14Page - Analog Devices ADP1877ACPZ-R7 Datasheet HTML 15Page - Analog Devices ADP1877ACPZ-R7 Datasheet HTML 16Page - Analog Devices ADP1877ACPZ-R7 Datasheet HTML 17Page - Analog Devices ADP1877ACPZ-R7 Datasheet HTML 18Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 32 page
background image
ADP1877
Rev. 0 | Page 14 of 32
MODE OF OPERATION
The SYNC pin is a multifunctional pin. PWM mode is enabled
when SYNC is connected to VCCO or a high logic. With SYNC
connected to ground or left floating, pulse skip mode is enabled.
Switching SYNC from low to high or high to low on the fly
causes the controller to transition from forced PWM to pulse
skip mode or pulse skip mode to forced PWM, respectively, in two
clock cycles.
Table 5. Mode of Operation Truth Table
SYNC Pin
Mode of Operation
Low
Pulse skip mode
High
Forced PWM
No Connect
Pulse skip mode
Clock Signal
Forced PWM
The ADP1877 has a built-in pulse skip sensing circuitry that
allows the controller to skip PWM pulses, thus reducing the
switching frequency at light loads and, therefore, maintaining
high efficiency during a light load operation. The switching
frequency is a fraction of the natural oscillator frequency and is
automatically adjusted to regulate the output voltage. The
resulting output ripple is larger than that of the fixed frequency
forced PWM. Figure 25 shows that the ADP1877 operates in
PSM under a light load of 10 mA. Pulse skip frequency under a
certain light load is dependent on the inductor input and output
voltages.
CH3 20mV
CH2 200mV
CH1 10V
CH4 2A Ω
M200µs
A CH1
7.8V
SW1
COMP1 (CH2)
VOUT RIPPLE
INDUCTOR
CURRENT
1
3
4
2
Figure 25. Example of Pulse Skip Mode Under a Light 5 mA Load
When the output load is greater than the pulse skip threshold
current (when VCOMP reaches the threshold of 0.9 V), the
ADP1877 exits the pulse skip mode operation and enters the
fixed frequency discontinuous conduction mode (DCM), as
shown in Figure 26. When the load increases further, the
ADP1877 enters CCM.
CH3 20mV
CH2 5V
CH1 10V
CH4 2A Ω
M1µs
A CH1
13.4V
DH1
DL1
OUTPUT
RIPPLE
INDUCTOR CURRENT
1
2
3
4
Figure 26. Example of Discontinuous Conduction Mode (DCM) Waveform
In forced PWM, the ADP1877 always operates in CCM at any
load. The inductor current is always continuous (and even goes
negative when there is no load); thus, efficiency is poor at light
loads.
SYNCHRONIZATION
The switching frequency of the ADP1877 can be synchronized
to an external clock by connecting SYNC to a clock signal,
which should be between 1× and 2.3× of the internal oscillator
frequency, fOSC. The resulting switching frequency, fSW, is ½ of
the external SYNC frequency because the SYNC input is
divided by 2, and the resulting phases are used to clock the two
channels alternately. In synchronization, the ADP1877 operates
in PWM, and fSW equals ½ of fSYNC.
When an external clock is detected at the first SYNC edge, the
internal oscillator is reset, and the clock control shifts to SYNC.
The SYNC edges then trigger subsequent clocking of the PWM
outputs. The DH1/DH2 rising edges appear approximately 100 ns
after the corresponding SYNC edge, and the frequency is locked
to the external signal. Depending on the start-up conditions of
Channel 1 and Channel 2, either Channel 1 or Channel 2 can be
the first channel synchronized to the rising edge of the SYNC
clock. If the external SYNC signal disappears during operation,
the ADP1877 reverts to its internal oscillator. When the SYNC
function is used, it is recommended to connect a pull-up
resistor from SYNC to VCCO so that when the SYNC signal is
lost, the ADP1877 continues to operate in PWM.
SOFT START
The soft start period is set by an external capacitor between
SS1/SS2 and AGND. When EN1/EN2 is enabled, a current source
of 6.5 μA starts charging the capacitor, and the regulation voltage is
reached when the voltage at SS1/SS2 reaches 0.6 V. For more
information, see the Applications Information section.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com