25 / 53 page ![]() SE97B_1 © NXP B.V. 2010. All rights reserved. Product data sheet Rev. 01 — 27 January 2010 25 of 53 NXP Semiconductors SE97B DDR memory module temp sensor with integrated SPD 8 SHMD Shutdown Mode. 0 — Temperature Sensor is active and converting (default). 1 — disabled Temperature Sensor will not generate interrupts or update the temperature data. When shut down, the thermal sensor diode and ADC are disabled to save power, no events will be generated. When either of the Critical Trip or Alarm Window lock bits is set, this bit cannot be set until unlocked. However, it can be cleared at any time. When in shutdown mode, the SE97B will still respond to commands normally. When coming out of shutdown, the EVENT output remains de-asserted as a new temperature conversion is done. Hysteresis is subtracted from the alarm thresholds if the temperature is falling but not used if the temperature is rising. The temperature trend will not be determined until at least two temperature conversions are done. Since all the alarm threshold flags (TEMP bits 13, 14, 15) are cleared with coming out of shutdown, it was decided to only apply hysteresis to the lower alarm threshold calculations when determining after the initial temperature conversion if the EVENT should assert. After the second temperature conversion the direction of temperature is known and TEMP bits 13, 14 or 15 are changed as required and the EVENT is asserted as required. 7 CTLB Critical Trip Lock bit. 0 — Critical Alarm Trip register is not locked and can be altered (default) 1 — Critical Alarm Trip register settings cannot be altered This bit is initially cleared. When set, this bit will return a ‘1’, and remains locked until cleared by internal Power-on reset. This bit can be written with a single write and does not require double writes. 6 AWLB Alarm Window Lock bit. 0 — Upper and Lower Alarm Trip registers are not locked and can be altered (default) 1 — Upper and Lower Alarm Trip registers setting cannot be altered This bit is initially cleared. When set, this bit will return a ‘1’ and remains locked until cleared by internal power-on reset. This bit can be written with a single write and does not require double writes. 5 CEVNT Clear EVENT (write only). 0 — no effect (default) 1 — clears active EVENT in Interrupt mode. Writing to this register has no effect in Comparator mode. If SMBUS[0] is a logic 0, the SMBus Alert Response Address (ARA) command can be sent to also clear the EVENT output. When read, this register always returns zero. 4 ESTAT EVENT Status (read only). 0 — EVENT output condition is not being asserted by this device (default) 1 — EVENT output pin is being asserted by this device due to Alarm Window or Critical Trip condition The actual event causing the event can be determined from the Read Temperature register. Interrupt Events can be cleared by writing to the ‘Clear EVENT’ bit (CEVNT) or SMBus Alert Response. Writing to this bit will have no effect. Table 13. Configuration register (address 01h) bit description …continued Bit Symbol Description |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |