| Electronic Components Datasheet Search |
|
SE97B Datasheet(PDF) 10 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
SE97B Datasheet(HTML) 10 Page - NXP Semiconductors |
|
10 / 53 page ![]() SE97B_1 © NXP B.V. 2010. All rights reserved. Product data sheet Rev. 01 — 27 January 2010 10 of 53 NXP Semiconductors SE97B DDR memory module temp sensor with integrated SPD 7.3.3 EVENT operation modes 7.3.3.1 Comparator mode In comparator mode, the EVENT output behaves like a window-comparator output that asserts when the temperature is outside the window (e.g., above the value programmed in the Upper Boundary Alarm Trip register or below the value programmed in the Lower Boundary Alarm Trip register or above the Critical Alarm Trip register if Tth(crit) only is selected). Reads/writes on these registers do not affect the EVENT output in comparator mode. The EVENT signal remains asserted until the temperature goes inside the alarm window or the window thresholds are reprogrammed so that the current temperature is within the alarm window. The comparator mode is useful for thermostat-type applications, such as turning on a cooling fan or triggering a system shutdown when the temperature exceeds a safe operating range. 7.3.3.2 Interrupt mode In interrupt mode, EVENT asserts whenever the temperature crosses an alarm window threshold. After such an event occurs, writing a 1 to the clear event bit in the configuration register de-asserts the EVENT output until the next trigger condition occurs. In interrupt mode, EVENT asserts when the temperature crosses the alarm upper boundary. If the EVENT output is cleared and the temperature continues to increase until it crosses the critical temperature threshold, EVENT asserts again. Because the temperature is greater than the critical temperature threshold, a clear event command does not clear the EVENT output. Once the temperature drops below the critical temperature, EVENT de-asserts immediately. If the EVENT output is not cleared before or when the temperature is in the critical temperature threshold, EVENT will remain asserted after the temperature drops below the critical temperature until a clear event command. 7.3.3.3 Switching between Comparator mode and Interrupt mode When the part is in Comparator mode and the temperature windows are set such that the BAW bit is set and the EVENT pin asserted (EventOutputControl = 1) and the part is switched to Interrupt mode, the EVENT is de-asserted. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |