Back Button MAX6876 Datasheet HTML 2Page - Maxim Integrated Products MAX6876 Datasheet HTML 3Page - Maxim Integrated Products MAX6876 Datasheet HTML 4Page - Maxim Integrated Products MAX6876 Datasheet HTML 5Page - Maxim Integrated Products MAX6876 Datasheet HTML 6Page - Maxim Integrated Products MAX6876 Datasheet HTML 7Page - Maxim Integrated Products MAX6876 Datasheet HTML 8Page - Maxim Integrated Products MAX6876 Datasheet HTML 9Page - Maxim Integrated Products MAX6876 Datasheet HTML 10Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 39 page
background image
EEPROM-Programmable, Quad,
Power-Supply Tracker/Sequencer Circuit
6
_______________________________________________________________________________________
Timing Diagrams
IN4 = 1.5V
IN3 = 1.8V
IN2 = 2.5V
IN1 = 3.3V
VTRKEN
GND
GND
GND
GND
FAULT
OUT4 = 1.5V
OUT3 = 1.8V
OUT2 = 2.5V
OUT1 = 3.3V
RESET
GND
BUS VOLTAGE MONITORED THROUGH TRKEN INPUT
VTRKEN
MONITORED THROUGH SET THRESHOLDS ON IN_
INPUTS (EEPROM-SELECTABLE)
tGATE
<tFAULTUP
tRESET
>tFAULTDOWN
EEPROM-
ADJUSTED
SLEW RATE
Figure 1. Tracking Timing Diagram
ELECTRICAL CHARACTERISTICS (continued)
(VCC, IN1–IN4 = +2.7V to +5.5V; ENABLE = MARGIN = MR = ABP = TRKEN; TA = -40°C to +85°C, unless otherwise specified.
Typical values are at TA = +25°C.) (Note 1)
Note 5: The MAX6876 programmed as a single device; GATE timeout has counted prior to beginning each sequence of power-up.
GATE timeout is not enabled during power-down or when the device is programmed as a master/slave.
Note 6: The MAX6876 programmed as a single device, the autoretry time begins to count at the assertion of the FAULT signal.
The MAX6876 programmed as a master/slave device; the autoretry time begins to count at the deassertion of the
common FAULT signal.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com