Back Button LT3486 Datasheet HTML 16Page - Linear Technology LT3486 Datasheet HTML 17Page - Linear Technology LT3486 Datasheet HTML 18Page - Linear Technology LT3486 Datasheet HTML 19Page - Linear Technology LT3486 Datasheet HTML 20Page - Linear Technology LT3486 Datasheet HTML 21Page - Linear Technology LT3486 Datasheet HTML 22Page - Linear Technology LT3486 Datasheet HTML 23Page - Linear Technology LT3486 Datasheet HTML 24Page - Linear Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 20 / 32 page
background image
LT3760
20
3760fc
applicaTions inForMaTion
Programming Overvoltage Protection (OVP) Level
The LT3760 LED driver provides optimum protection to
the LEDs and the external MOSFET by providing a pro-
grammablemaximumregulatedoutputvoltagelimitusing
the OVPSET pin. The Overvoltage Protection (OVP) level
is programmed as:
OVP(MAXIMUM REGULATED VOUT) = 57 • OVPSET
If every LED string fails open or the multiple string LED
displaybecomesdisconnectedtheLT3760LEDdriverloop
regulates to the programmed OVP level. The OVP level
should be programmed to a level high enough to regulate
the LED strings but low enough to prevent damage to the
power switch and to minimize the voltage across the LED
pinsuponreconnectionoftheLEDstrings.Recommended
OVP level is given by:
OVP(RECOMMENDED) = 1.2 • ((N • VF) + 1V)
where:
N = number of LEDs in each string,
VF = maximum LED forward voltage drop
and the scaling factor of 1.2 accounts for variation in the
generation of OVP from OVPSET pin voltage and startup
logic requirements.
Example:Foraconverteroperatingwith10LEDsperstring
at a maximum forward voltage of 4V per LED, the OVP
level should be programmed to:
OVP(RECOMMENDED)
= 1.2 • (10 • 4)+ 1V
(
) = 49.2V
For OVP
= 49.2V, OVPSET =
49.2
57
= 0.863V
The OVPSET pin voltage can be generated using a resistor
divider from the REF pin.
LED Open Circuit and PWM Dimming Ratios
The LT3760 monitors each LED pin voltage to determine if
the LED string has an open fault (LED pin voltage < 0.5V).
If an open LED fault occurs, the FAULT flag is pulled low.
Toavoidfalsedetectionoffaultsduringtheinitialconverter
startup when VOUT is low, the LT3760 ignores low LED
pin voltages until VOUT reaches 90% of its maximum al-
lowed OVP level. Once this condition is met, the LT3760
monitors all LED pins for open LED faults. To avoid false
detection of faults during PWM dimming edges (where
LED pins can possibly ring and trip fault detection levels)
the LT3760 only monitors/updates fault conditions during
PWM high (and only after a blank duration of 2µs following
each PWM rising edge).
LED Short Circuit
A short circuit fault between the positive terminal of an
LED string (VOUT) and the negative terminal of the LED
string (LEDx pin) causes the channel to be disabled in
order to protect the internal current source. A resistive
short is allowed as long as (VOUT-VLEDx) < 6V.
Loop Compensation
Be sure to check the stability of the loop with the LEDs
connected (LED regulation loop) and disconnected
(Overvoltage Protection (OVP) regulation loop). Various
application circuits are shown in the data sheet which
coverarangeofVIN,VOUT,fOSC,outputpowerandinductor
current ripple values. For application requirements which
deviate from the circuits shown in the data sheet be sure
to check the stability of the final application over the full
VIN range, LED current range (if analog dimming) and
temperature range. Be aware that if the VCpincomponents
represent a dominant pole for the converter loop and they
have been adjusted to achieve stability, the VC pin might
move more slowly during load transient conditions such
as an all-LEDs-open fault. A slower moving VC pin will
add to VOUT overshoot during an all-LEDs-open fault.
An alternative compensation approach is to place the
dominant pole of the converter loop at the output. This
requires an increased output capacitor value but will allow
a much reduced Vc capacitor. The combination will allow
VC to move more quickly and VOUT to move more slowly
resulting in less overshoot during an all-LEDs-open fault.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com