| Electronic Components Datasheet Search |
|
LT1640AL Datasheet(PDF) 17 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LT1640AL Datasheet(HTML) 17 Page - Linear Technology |
|
17 / 36 page ![]() LTC4252-1/LTC4252-2 LTC4252A-1/LTC4252A-2 17 425212fd APPLICATIONS INFORMATION 2.5% or more will eventually trip the circuit breaker and shut down the LTC4252. Figure 5 shows the circuit breaker response time in seconds normalized to 1μF for IDRN = 0μA. The asymmetric charging and discharging of CT is a fair gauge of MOSFET heating. The normalized circuit response time is estimated by t CT (μF) = 4 235.8+8 •IDRN ()•D–5.8 ⎡⎣ ⎤⎦ (4) SHUTDOWN COOLING CYCLE For the LTC4252-1 (latchoff version), TIMER latches high with a 5.8μA pull-up after the circuit breaker fault TIMER reaches 4V. For the LTC4252-2 (automatic retry version), a shutdown cooling cycle begins if TIMER reaches the 4V threshold. TIMER starts with a 5.8μA pull-down until it reaches the 1V threshold. Then, the 5.8μA pull-up turns back on until TIMER reaches the 4V threshold. Four 5.8μA pull-down cycles and three 5.8μA pull-up cycles occur between the 1V and 4V thresholds, creating a time interval given by: tSHUTDOWN = 7• 3V •CT 5.8μA (5) At the 1V threshold of the last pull-down cycle, a GATE ramp-up is attempted. SOFT-START Soft-start limits the inrush current profile during GATE start-up. Unduly long soft-start intervals can exceed the MOSFET’s SOA rating if powering up into an active load. If SS floats, an internal current source ramps SS from 0V to 2.2V for the LTC4252 or 0V to 1.4V for the LTC4252A in about 230μs. Connecting an external capacitor CSS from SS to ground modifies the ramp to approximate an RC response of: VSS (t)≈VSS • 1–e – t RSS •CSS ⎛ ⎝⎜ ⎞ ⎠⎟ ⎛ ⎝ ⎜ ⎜ ⎜ ⎞ ⎠ ⎟ ⎟ ⎟ (6) An internal resistive divider (95k/5k for the LTC4252 or 47.5k/2.5k for the LTC4252A) scales VSS(t) down by 20 times to give the analog current limit threshold: VACL (t)= VSS (t) 20 –VOS (7) This allows the inrush current to be limited to VACL(t)/RS. The offset voltage, VOS (10mV), ensures CSS is sufficiently discharged and the ACL amplifier is in current limit before GATE start-up. SS is pulled low under any of the following conditions: in UVLO, in an undervoltage condition, in an overvoltage condition, during the initial timing cycle or when the circuit breaker fault times out. GATE GATE is pulled low to VEE under any of the following conditions: in UVLO, in an undervoltage condition, in an overvoltage condition, during the initial timing cycle or when the circuit breaker fault times out. When GATE turns on, a 58μA current source charges the MOSFET gate and any associated external capacitance. VIN limits the gate drive to no more than 14.5V. Gate-drain capacitance (CGD) feedthrough at the first abrupt application of power can cause a gate-source voltage sufficient to turn on the MOSFET. A unique circuit pulls GATE low with practically no usable voltage at VIN FAULT DUTY CYCLE (%) 0 20406080 100 10 1 0.1 0.01 425212 F05 = 4 DRN t CT(μF) IDRN = 0μA Figure 5. Circuit-Breaker Response Time |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |