Back Button ADF4106 Datasheet HTML 12Page - Analog Devices ADF4106 Datasheet HTML 13Page - Analog Devices ADF4106 Datasheet HTML 14Page - Analog Devices ADF4106 Datasheet HTML 15Page - Analog Devices ADF4106 Datasheet HTML 16Page - Analog Devices ADF4106 Datasheet HTML 17Page - Analog Devices ADF4106 Datasheet HTML 18Page - Analog Devices ADF4106 Datasheet HTML 19Page - Analog Devices ADF4106 Datasheet HTML 20Page - Analog Devices  
Zoom Inzoom in Zoom Outzoom out
 18 / 20 page
background image
REV. 0
ADF4106
–18–
On first applying power to the ADF4106, it needs at three writes
(one each to the R counter latch, the N counter latch and the
function latch) for the output to become active.
I/O port lines on the ADuC812 are also used to control
power-down (CE input) and to detect lock (MUXOUT config-
ured as lock detect and polled by the port input).
When operating in the mode described, the maximum SCLOCK
rate of the ADuC812 is 4 MHz. This means that the maximum
rate at which the output frequency can be changed will be 166 kHz.
ADuC812
ADF4106
SCLK
SDATA
LE
CE
MUXOUT
(LOCK DETECT)
SCLOCK
MOSI
I/O PORTS
Figure 8. ADuC812 to ADF4106 Interface
ADSP-2181 Interface
Figure 9 shows the interface between the ADF4106 and the
ADSP-21xx Digital Signal Processor. The ADF4106 needs a
24-bit serial word for each latch write. The easiest way to
accomplish this using the ADSP-21xx family is to use the
Autobuffered Transmit Mode of operation with Alternate Framing.
This provides a means for transmitting an entire block of serial
data before an interrupt is generated. Set up the word length for
8 bits and use three memory locations for each 24-bit word. To
program each 24-bit latch, store the three 8-bit bytes, enable the
Autobuffered mode and then write to the transmit register of the
DSP. This last operation initiates the autobuffer transfer.
ADSP-21xx
ADF4106
SCLK
SDATA
LE
CE
MUXOUT
(LOCK DETECT)
SCLOCK
MOSI
I/O FLAGS
TFS
Figure 9. ADSP-21xx to ADF4106 Interface



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com