| Electronic Components Datasheet Search |
|
MA17501 Datasheet(PDF) 12 Page - Dynex Semiconductor |
|
|
|||||||||||||||||||||||||||||
MA17501 Datasheet(HTML) 12 Page - Dynex Semiconductor |
|
12 / 35 page ![]() MA17501 12/35 Operand transfers use the address register (A), data input register (Dl), and data output register (DO). Before the operand transfer begins, the Execution Unit calculates the effective operand address and stores this value in A. For write transfers the EU loads the operand into DO. For operand ready cycles the EU latches the operand from the AD Bus into Dl at the SYSCLK1N high-to-low transition. All operand transfers between the MAS281 and memory are referenced to the AS and DSN bus control signals and are characterised by lN/OPN low, M/lON and CDN high, and RD/ WN (high, read; low, write). The EU first places the contents of A on the AD Bus at the SYSCLK1N high-to-low transition. Shortly following, AS is raised high to enable the system address bus transparent latch. This address is assured valid at the high-to-low transition of AS. At the SYSCLK1N low-to high transition, DSN drops low to indicate the contents of DO have been placed on the AD Bus (write) or the EU AD Bus drivers have been placed in the high impedance state (read). DSN subsequently raises high when the output data is stable, prior to SYSCLK1N dropping low, or raises high in response to SYSCLK1N dropping low to indicate the EU's acceptance of the input data. All operand transfer cycles are allowed to complete via the RDYN input. During the data portion of the cycle the EU assumes memory is NOT READY, and requires RDYN low to signal the memory’s readiness to complete the cycle. If RDYN is high at the high-to-low transition of the fifth OSC cycle within the operand transfer cycle, a wait state will be injected (one OSC period at a time) for each OSC high-to-low transition that RDYN remains high. Memory readiness, thus cycle completion, is signalled by RDYN low enveloping a subsequent OSC high-to-low transition. 4.2.4 Input/Output Transfers Input/Output transfers are characterised by M/lON and IN/ OPN low, and RD/WN (high, input; low, output). AS and DSN operate as during operand transfers. Two different types of input/output transfers are controlled by the Execution Unit: internal and external. Internal l/O transfers involve all XlO commands that are decoded by the lnterrupt Unit (lU) and use the local AD Bus to transfer response data. These commands are listed in Table 3 (the only exception is RCW; it is an lU decoded, lRDYN completed, External l/O command). Internal XlO commands implemented in the lU (per Table 3) use a six OSC period machine cycle and the IRDYN cycle completion input. lnternal XlO commands implemented in the MA31751 MMU/BPU use a minimum five OSC period machine cycle. The system RDYN generator provides the RDYN cycle completion input to the EU. The term "local AD Bus" in this context refers to the AD Bus on the processor side of the system data bus demultiplexing transceivers. The three chips of the MAS281 and the MA17504 (in either configuration) reside on the local AD Bus and communicate to the user system through the required address and data bus buffers, as depicted in Figure 4. External I/O transfers involve all XlO and VlO instructions not included under lnternal l/O transfers. They execute during a minimum five OSC period machine cycle that is extendible via RDYN, as previously described. 4.3 INTERRUPT SERVICING Interrupts are latched into the lnterrupt Unit (lU) pending interrupt register by the SYNCLKN high-to-low transition. The lU signals the Control Unit (CU) that an interrupt is pending and the CU branches to the microcoded interrupt handling routine at the completion of the currently executing MlL-STD- 1750A instruction. The EU supports the interrupt handling routine by enabling microcode control of the lU at the proper time via the lNTREN signal and by calculating the memory addresses of the service and linkage pointers based on the 4-bit interrupt priority code transmitted by the IU. Machine cycles during which lNTREN is low are six OSC periods in length. During these lNTREN cycles, DSN and M/lON are high, and AS is low. The EU also provides a hardwired interrupt to the lU. the OVIN interrupt signals a fixed-point arithmetic overflow. 4.4 FAULT SERVICING The Interrupt Unit (IU) latches fault inputs into the fault register on the high-to-low transition of SYNCLKN. Faults other than 0, 5, and 8 latch a level one pending interrupt in the lU and the interrupt sequencing proceeds as previously explained. Faults 0, 5, and 8 caused during non-DMA AD Bus transactions demand more immediate attention; the MlL-STD-1750A instruction during which the fault occurred must be aborted. PIFN indicates to the Control Unit that one of these faults has occurred and forces a branch to the “next instruction fetch’’ microinstruction so that the interrupt caused by the PlFN fault can be serviced immediately. Under normal instruction execution circumstances, the bus control signals would operate during the machine cycle between the fault and the instruction fetch machine cycle. PlFN causes the bus control signals AS and DSN to stay in their inactive state during this transitional machine cycle to allow the branch to the microcoded interrupt routine without performing any AD Bus transactions. 4.5 DIRECT MEMORY ACCESS The Interrupt Unit DMA interface logic signals the Execution Unit (EU) that it has acknowledged a DMA request (PAUSEN low). PAUSEN low causes the EU to halt the synchronisation clocks CLK02N (high), CLKPCN (low), and SYSCLK1N (low); disables clock generation circuitry input that could vary the machine cycle length; and places all bus control signals and the AD Bus in the high impedance state. The SYNCN and SYNCLKN clocks continue to operate with a five OSC cycle period. Upon removal of PAUSEN by the Interrupt Unit, the MAS281 resumes microinstruction execution where it was interrupted. 4.6 SOFTWARE DEVELOPMENT SUPPORT The Execution Unit responds to a HOLDN signal by suspending all internal operations upon completion of the currently executing instruction. Microcode, from the Control Unit, directs HLDAKN low during the third SYNCN cycle after HOLDN has been pulled low and the previous instruction has been completed. M/lON, RD/WN, IN/OPN, AS, DSN, and the AD Bus are placed in the high impedance state permitting a monitor system to take control of the memory/input-output system. Raising HOLDN releases the MAS281 from the Hold state and instruction execution begins by refilling the pipeline. The execution of a BPT instruction also causes HLDAKN to drop low and the bus control signals and AD Bus to be placed in the high impedance state. A low pulse on HOLDN releases the MAS281 from the BPT initiated Hold state. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |