| Electronic Components Datasheet Search |
|
AS8506C Datasheet(PDF) 31 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8506C Datasheet(HTML) 31 Page - ams AG |
|
31 / 94 page ![]() ams Datasheet: 2014-Jun-23 [v1-00] AS8506C – 31 Detaile d Desc rip t ion At the end of the Diagnosis phase, if trigger signal is ‘High’ then it enters into Balance phase. If trigger signal is ‘Low’ it enters into WAIT mode. The Diagnosis phase without the cell voltage and temperature measurement with SAR ADC is called Compare phase. Compare and Balance Phase The Balance phase is basically a charging cycle in case of active balancing and a discharging cycle in case of passive balancing. The Balance phase is divided into 7 time slots. The device will move through all 7 time slots irrespective of number of cells connected to the device. This is done to keep synchronization between each module in case of battery stack system. One time slot is assigned to each cell (sequential order) for charging or discharging. The period of time slots is programmable (see “Status Registers” on page 53). In each time slot, following operations are done. • Check CVT_NOK flag status. If CVT_NOK flag is set, then no operation is done till time slot is over. If CVT_NOK flag is not set, then move to the next step. • Based on Diagnosis phase results, shuttle switch corresponding to current time slot cell is switched ON for charging that cell in case of active balancing, and discharging in case of passive balancing. • The PWM generator is enabled and PWM driver start driving the Flyback converter FET (external component) in case of active balancing. The PWM frequency and duty cycles are factory programmable and also register controllable. In case of stack system, the bottom module PWM driver is enabled when there is a request of charging or discharging from top module on FD_OUT pin. • At the end of the current time slot, stop the PWM generator and then open the corresponding shuttle switches. The device moves to the next time slot. In the Balance phase, at any point, if the trigger input goes ‘Low’, then the device suspends balancing operation and enters into WAIT mode. An example of Compare and Balance (active balance) phase sequence with respect to time is given in Figure 25. In this example it is assumed that only 6 cells are connected to AS8506C and comparators’ outputs at Diagnosis phase is “010010X”; Where: ‘0’ indicates respective cell voltage is less than target voltage and needs charging. ‘1’ indicates respective cell voltage is more than target voltage and charging is not needed. ‘X’ indicates no cell is connected to respective comparator and output is neglected. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |