Back Button MAX521 Datasheet HTML 8Page - Maxim Integrated Products MAX521 Datasheet HTML 9Page - Maxim Integrated Products MAX521 Datasheet HTML 10Page - Maxim Integrated Products MAX521 Datasheet HTML 11Page - Maxim Integrated Products MAX521 Datasheet HTML 12Page - Maxim Integrated Products MAX521 Datasheet HTML 13Page - Maxim Integrated Products MAX521 Datasheet HTML 14Page - Maxim Integrated Products MAX521 Datasheet HTML 15Page - Maxim Integrated Products MAX521 Datasheet HTML 16Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 12 / 20 page
background image
Quad/Octal, 2-Wire Serial 8-Bit DACs
with Rail-to-Rail Outputs
12
______________________________________________________________________________________
(
)
(
)
SDA
SDA
0
START
CONDITION
ADDRESS BYTE
ACK
ACK
1
0
1
AD1 AD0 0
0
00
00000
0
0
1
1
11111
1
0 0
10000
0
0
0
0
0
00
0
0
0
0
1
0
00
00
00
00
1
1
11
11
11
1
STOP
CONDITION
OUTPUT BYTE
(FULL SCALE)
COMMAND BYTE
(ADDRESSING DAC0)
ACK
OUTPUT BYTE
(FULL SCALE)
ACK
COMMAND BYTE
(ADDRESSING DAC2)
ACK
OUTPUT BYTE
(HALF SCALE)
ACK
COMMAND BYTE
(ADDRESSING DAC1)
ACK
DAC OUTPUTS CHANGE HERE:
DACS 0 AND 1 GO TO FULL SCALE,
DAC 2 GOES TO HALF SCALE.
DAC0 INPUT LATCH
SET TO FULL SCALE
(
)
(
)
DAC2 INPUT LATCH
SET TO HALF SCALE
DAC1 INPUT LATCH
SET TO FULL SCALE
0 OR AD2
Figure 7. Setting DAC Outputs
SDA
0
START
CONDITION
ADDRESS BYTE
ACK
1
0
1
AD1 AD0 0
0
0
0 0001
(PD)
(PD)
STOP
CONDITION
COMMAND BYTE
ACK
DEVICE ENTERS
POWER-DOWN STATE
(
)
SDA
0
START
CONDITION
ADDRESS BYTE
ACK
1
0
1
AD1 AD0 0
0
0
0
000010
0
0
1
11
1
1
11
1
STOP
CONDITION
COMMAND BYTE
(ADDRESSING DAC0)
ACK
OUTPUT BYTE
(FULL SCALE)
ACK
(a)
(b)
DEVICE ENTERS POWER-DOWN STATE.
DAC 0 OUTPUT LATCH SET TO FULL SCALE.
NOTE: X = DON'T CARE
DAC 0 INPUT LATCH
SET TO FULL SCALE
X
X
X
(
)
(
)
0 OR AD2
0 OR AD2
Figure 8. Entering the Power-Down State
(
)
SDA
0
START
CONDITION
ADDRESS BYTE
ACK
1
0
1
AD1 AD0 0
0
0
0 0000
(PD)
(PD)
STOP
CONDITION
COMMAND BYTE
ACK
DEVICE RETURNS TO
NORMAL OPERATION
(
)
DAC3 OUTPUT
LATCH SET TO 0
SDA
0
START
CONDITION
ADDRESS BYTE
ACK
1
0
1
AD1 AD0 0
0
0
00000
1
1
0
0
0
0
00
00
00
STOP
CONDITION
COMMAND BYTE
(ADDRESSING DAC3)
ACK
OUTPUT BYTE
(SET TO 0)
ACK
(a)
(b)
DEVICE RETURNS TO NORMAL OPERATION.
DAC 3 SET TO 0.
NOTE: X = DON'T CARE
X
X
X
(
)
0 OR AD2
0 OR AD2
Figure 9. Returning to Normal Operation from Power-Down



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com