| Electronic Components Datasheet Search |
|
W989D6KB Datasheet(PDF) 53 Page - Winbond |
|
|
|||||||||||||||||||||||||||||
W989D6KB Datasheet(HTML) 53 Page - Winbond |
|
53 / 66 page ![]() W989D6KB / W989D2KB 512Mb Mobile LPSDR Publication Release Date : October 07, 2013 - 53 - Revision : A01-003 11.13 Power Down Mode 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 RAa CAa RAa CAx RAa RAa ax0 ax1 ax2 ax3 tSB tCKS tCKS tCKS tSB tCKS Active Power Down Mode Exit Precharge & Power Down Mode Entry Device Deselect Active Note: The PowerDown Mode is entered by asserting CKE "low". All Input/Output buffers (except CKE buffers) are turned off in the Power Down mode. When CKE goes high, command input must be No operation at next CLK rising edge. Violating refresh requirements during power-down may result in a loss of data. CLK DQ CKE DQM Address A10 BA WE CAS RAS CS DSL Power Down Mode Exit Power Down Mode Entry |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|