| Electronic Components Datasheet Search |
|
W989D6KB Datasheet(PDF) 24 Page - Winbond |
|
|
|||||||||||||||||||||||||||||
W989D6KB Datasheet(HTML) 24 Page - Winbond |
|
24 / 66 page ![]() W989D6KB / W989D2KB 512Mb Mobile LPSDR Publication Release Date : October 07, 2013 - 24 - Revision : A01-003 9.3 Precharge There are two commands which perform the Precharge operation: Bank Precharge and Precharge All. When the Bank Precharge command is issued to the active bank, the bank is precharged and then switched to the idle state. The Bank Precharge command can precharge one bank independently of the other bank and hold the unprecharged bank in the active state. The maximum time each bank can be held in the active state is specified as tRAS (max). Therefore, each bank must be precharged within tRAS (max) from the Bank Activate command. The Precharge All command can be used to precharge all banks simultaneously. Even if banks are not in the active state, the Precharge All command can still be issued. In this case, the Precharge operation is performed only for the active bank and the precharged bank is then switched to the idle state. 9.3.1 Auto Precharge Auto precharge is a feature that performs the same individual-bank PRECHARGE function described previously, without requiring an explicit command. This is accomplished by using A10 to enable auto precharge in conjunction with a specific READ or WRITE command. A precharge of the bank/row that is addressed with the READ or WRITE command is automatically performed upon completion of the READ or WRITE burst, except in the continuous page burst mode where auto precharge does not apply. In the specific case of write burst mode set to single location access with burst length set to continuous, the burst length setting is the overriding setting and auto precharge does not apply. Auto precharge is nonpersistent in that it is either enabled or disabled for each individual READ or WRITE command. Auto precharge ensures that the precharge is initiated at the earliest valid stage within a burst. Another command cannot be issued to the same bank until the precharge time (tRP) is completed. This is determined as if an explicit PRECHARGE command was issued at the earliest possible time. Winbond SDRAM supports concurrent auto precharge; cases of concurrent auto precharge for READs and WRITEs are defined below. 9.3.2 READ with auto precharge interrupted by a READ (with or without auto precharge) A READ to bank m will interrupt a READ on bank n following the programmed CAS latency. The precharge to bank n begins when the READ to bank m is registered CLK T0 T1 T2 T3 T4 T5 T6 T7 Command Bank n Bank m Address DQ Internal states NOP NOP NOP NOP NOP NOP Idle Dout a Bank n, Col a Bank m, Col d tRP-bank m Precharge tRP-bank n READ-AP Bank m READ with burst of 4 Interrupt burst, precharge READ with burst of 4 Page active Page active READ-AP Bank n CL=3 (bank n) CL=3 (bank m) Don’t Care Note: 1. DQM is LOW. Dout a+1 Dout d Dout d+1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |