Back Button W989D6KB Datasheet HTML 19Page - Winbond W989D6KB Datasheet HTML 20Page - Winbond W989D6KB Datasheet HTML 21Page - Winbond W989D6KB Datasheet HTML 22Page - Winbond W989D6KB Datasheet HTML 23Page - Winbond W989D6KB Datasheet HTML 24Page - Winbond W989D6KB Datasheet HTML 25Page - Winbond W989D6KB Datasheet HTML 26Page - Winbond W989D6KB Datasheet HTML 27Page - Winbond Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 66 page
background image
W989D6KB / W989D2KB
512Mb Mobile LPSDR
Publication Release Date : October 07, 2013
- 23 -
Revision : A01-003
8.1.20 Clock Suspend Mode Exit/Power Down Mode Exit Command
(CKE = H)
When the internal CLK has been suspended, operation of the internal CLK is resumed by providing this command (asserting
CKE “high”). When the device is in Power Down mode, the device exits this mode and all disabled buffers are turned on to the
active state. Any subsequent commands can be issued after one clock cycle from the end of this command.
8.1.21 Data Write/Output Enable, Data Mask/Output Disable Command
(DQM = L/H or LDQM, UDQM = L/H or DQM0-3=L/H)
During a Write cycle, the DQM or LDQM, UDQM or DQM0-3 signals mask write data. Each of these signals control the input
buffers per byte. During a Read cycle, the DQM or LDQM, UDQM or DQM0-3 signals control of the output buffers per byte.
I/O Org.
Mask Pin
Masked DQs
×16
LDQM
DQ0~DQ7
UDQM:
DQ8~DQ15
×32
DQM0:
DQ0~DQ7
DQM1:
DQ8~DQ15
DQM2:
DQ16~DQ23
DQM3:
DQ24~DQ31
9.OPERATION
9.1 Read Operation
Issuing the Bank Activate command to the idle bank puts it into the active state. When the Read command is issued after tRCD from
the Bank Activate command, the data is read out sequentially, synchronized to the positive edges of CLK (a Burst Read operation).
The initial read data becomes available after
CAS Latency from the issuing of the Read command. The CAS latency must be
set in the Mode Register at power-up. In addition, the burst length of read data and Addressing Mode must be set. Each bank is
held in the active state unless the Precharge command is issued, so that the sense amplifiers can be used as secondary cache.
When the Read with Auto Precharge command is issued, the Precharge operation is performed automatically after the Read cycle,
then the bank is switched to the idle state. This command cannot be interrupted by any other commands. Also, when the Burst
Length is 1 and tRCD (min), the timing from the RAS command to the start of the Auto Precharge operation is shorter than tRAS
(min). In this case, tRAS (min) must be satisfied by extending tRCD.
When the Precharge operation is performed on a bank during a Burst Read operation, the Burst operation is terminated.
When the Burst Length is full-page, column data is repeatedly read out until the Burst Stop command or Precharge command is
issued.
9.2 Write Operation
Issuing the Write command after tRCD from the Bank Activate command, the input data is latched sequentially, synchronizing with
the positive edges of CLK after the Write command (Burst Write operation). The burst length of the Write data (Burst Length) and
Addressing Mode must be set in the Mode Register at power-up.
When the Write with Auto Precharge command is issued, the Precharge operation is performed automatically after the Write cycle,
then the bank is switched to the idle state. This command cannot be interrupted by any other command for the entire burst data
duration. Also, when the Burst Length is 1 and tRCD (min), the timing from the RAS command to the start of the Auto Precharge
operation is shorter than tRAS (min). In this case, tRAS (min) must be satisfied by extending tRCD.
When the Precharge operation is performed in a bank during a Burst Write operation, the Burst operation is terminated.
When the Burst Length is full-page, the input data is repeatedly latched until the Burst Stop command or the Precharge command is
issued.
When the Burst Read and Single Write mode is selected, the write burst length is 1 regardless of the read burst length.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com