Back Button DLPA2000 Datasheet HTML 25Page - Texas Instruments DLPA2000 Datasheet HTML 26Page - Texas Instruments DLPA2000 Datasheet HTML 27Page - Texas Instruments DLPA2000 Datasheet HTML 28Page - Texas Instruments DLPA2000 Datasheet HTML 29Page - Texas Instruments DLPA2000 Datasheet HTML 30Page - Texas Instruments DLPA2000 Datasheet HTML 31Page - Texas Instruments DLPA2000 Datasheet HTML 32Page - Texas Instruments DLPA2000 Datasheet HTML 33Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 29 / 41 page
background image
29
DLP2010
www.ti.com
DLPS046B – JULY 2014 – REVISED JULY 2016
Product Folder Links: DLP2010
Submit Documentation Feedback
Copyright © 2014–2016, Texas Instruments Incorporated
9 Power Supply Recommendations
The following power supplies are all required to operate the DMD: VSS, VDD, VDDI, VOFFSET, VBIAS, and
VRESET. DMD power-up and power-down sequencing is strictly controlled by the DLPA2000 or DLPA2005
device.
CAUTION
For reliable operation of the DMD, the following power supply sequencing
requirements must be followed. Failure to adhere to the prescribed power-up and
power-down procedures may affect device reliability.
VDD, VDDI, VOFFSET, VBIAS, and VRESET power supplies have to be coordinated
during power-up and power-down operations. Failure to meet any of the below
requirements will result in a significant reduction in the DMD’s reliability and lifetime.
Refer to Figure 23. VSS must also be connected.
9.1 Power Supply Power-Up Procedure
•
During power-up, VDD and VDDI must always start and settle before VOFFSET, VBIAS, and VRESET
voltages are applied to the DMD.
•
During power-up, it is a strict requirement that the delta between VBIAS and VOFFSET must be within the
specified limit shown in Recommended Operating Conditions. Refer to Table 3 and the Layout Example for
power-up delay requirements.
•
During power-up, the DMD’s LPSDR input pins shall not be driven high until after VDD and VDDI have settled
at operating voltage.
•
During power-up, there is no requirement for the relative timing of VRESET with respect to VOFFSET and
VBIAS. Power supply slew rates during power-up are flexible, provided that the transient voltage levels follow
the requirements listed previously and in Figure 22.
9.2 Power Supply Power-Down Procedure
•
Power-down sequence is the reverse order of the previous power-up sequence. VDD and VDDI must be
supplied until after VBIAS, VRESET, and VOFFSET are discharged to within 4 V of ground.
•
During power-down, it is not mandatory to stop driving VBIAS prior to VOFFSET, but it is a strict requirement
that the delta between VBIAS and VOFFSET must be within the specified limit shown in Recommended
Operating Conditions (Refer to Note 2 for Figure 22).
•
During power-down, the DMD’s LPSDR input pins must be less than VDDI, the specified limit shown in
Recommended Operating Conditions.
•
During power-down, there is no requirement for the relative timing of VRESET with respect to VOFFSET and
VBIAS.
•
Power supply slew rates during power-down are flexible, provided that the transient voltage levels follow the
requirements listed previously and in Figure 22.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com