| Electronic Components Datasheet Search |
|
PI3749 Datasheet(PDF) 21 Page - Vicor Corporation |
|
|
|||||||||||||||||||||||||||||
PI3749 Datasheet(HTML) 21 Page - Vicor Corporation |
|
21 / 26 page ![]() Cool-Power® ZVS Switching Regulators Rev 1.6 vicorpower.com Page 21 of 26 09/2016 800 927.9474 PI3749-x0 I2C Parameter Readback Fault Monitoring The fault bits in the FLT2 and FLT3 registers are only latched when the regulator first stops operating due to a given fault type. If the regulator is already not operating (perhaps due to a fault protection or being disabled) then should a new fault condition occur, the fault bit associated with the new fault will not be registered. Both versions of the PI3749-x0 will auto recover from any fault protection mechanism, once the fault is corrected. However in order to aid in monitoring of the regulator via the I2C fault monitoring registers, when a fault occurs, the associated fault bit(s) will set and latch until they are explicitly cleared by the I2C host using the FLTREG_CLR register. A write to the FLTREG_CLR register address will clear all latched fault register bits. I2C Volatile Addresses for Parameter Programming Register Name Register Address Bit <7> Bit <6> Bit <5> Bit <4> Bit <3> Bit <2> Bit <1> Bit <0> FLT2 2 TRISE OTP VOUT_NEG VOUT_OV EAIN_HI VIN_OV VIN_UV VCC_UV FLT3 3 0 0 0 0 Q1_FIL Q3_SIL Q3_FIL SLOW_IL FLTREG_CLR 4 Write only, data ignored Table 4 — PI3749-20 Fault Readback/Clear Registers Fault Bit Name Fault Bit Location Fault Destination TRISE FLT2, Bit<7> Overtemperature Protection: The predicted maximum hot-spot temperature, based on measured temperature and loading, exceeded the maximum safe operating temperature. OTP FLT2, Bit<6> Overtemperature Protection: The internal measured temperature exceeded the maximum safe operating temperature. VOUT_NEG FLT2, Bit<5> VOUT negative fault. The output voltage was below ground. VOUT_OV FLT2, Bit<4> Output Overvoltage protection. EAIN_HI FLT2, Bit<3> Current Limit: Overload Timeout. VIN_OV FLT2, Bit<2> Input Overvoltage Lockout. VIN_UV FLT2, Bit<1> Input Undervoltage Lockout. VCC_UV FLT2, Bit<0> VCC undervoltage. The internal bias supply faulted due to undervoltage. Q1_FIL FLT3, Bit<3> Current Limit: Fast current limit (Q1) The peak current through Q1 and the inductor was higher than the maximum current allowed. Q3_SIL FLT3, Bit<2> Current Limit: Slow current limit (Q3) Q3_FIL FLT3, Bit<1> Current Limit: Fast current limit (Q3) The peak current through Q3 and the inductor was higher than the maximum current allowed. SLOW_IL FLT3, Bit<0> Current Limit: Slow current limit. Register Name Register Address Readback capable? Bit <3> Bit <2> Bit <1> Bit <0> MRGN 5 Yes MRGN_ENA MRGN<2> MRGN<1> MRGN<0> Table 6 — PI3749-20 Parameter Programming Volatile Registers Table 5 — Fault register bit summary |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |