7 / 50 page ![]() MYSON TECHNOLOGY MTL005 Rev 0.9 Revision 0.9 - 7 - 2000/12/29 ¨ V/H SYNC Frequency Counter MTL005 can measure VSYNC/HSYNC frequency counted in proper clocks and save the information in registers. Users can read it out to calculate VSYNC/HSYNC frequency as in the following formulas: f vsync = fosc / Nvsync 51/256 f hsync = fosc / Nhsync 58 ,Where f vsync : VSYNC frequency f hsync : HSYNC frequency f osc : oscillator clock with 14.31818 MHz N vsync : counted number of VSYNC N hsync : counted number of HSYNC ¨ V/H SYNC Presence Check This function checks the input VSYNC, where Vpre flag is set when VSYNC is over 40Hz or cleared when VSYNC is under 10Hz ,and the input HSYNC, where Hpre flag is set when HSYNC is over 10Khz or cleared when HSYNC is under 10Hz. ¨ V/H Polarity Detect This function detects the input VSYNC/HSYNC high and low pulse duty cycle. If the high pulse duration is longer than that of the low pulse, the negative polarity is asserted; otherwise, positive polarity is asserted. ¨ Composite SYNC separation/insertion MTL005 continuously monitors the input HSYNC. If the input VSYNC can be extracted from it, a CVpre flag is set. MTL005 can insert HSYNC pulse during Composite VSYNC’s active time and the insertion frequency can adapt to original HSYNC’s. 3.1.8 Auto Tune Auto Tune function consists of Auto Position automatically centering the screen and Auto Calibration containing Phase Calibration, Histogram, Min/Max Value, and Pixel Grab described as below. With this auto adjustment support it is possible to measure the correct phase, frequency, gain, and offset of ADC. The horizontal and vertical back porches of input image and the horizontal and vertical active regions can also be measured. Firmware can adjust input image registers automatically by reading Auto Tune’s registers in single or burst mode. ¨ Auto Position MTL005 provides Horizontal/Vertical back porch and active region values. Users can use these values to set input sample registers to aid in centering the screen automatically. ¨ Phase Calibration MTL005 provides Auto Calibration registers to measure the quality of current ADC’s phase and frequency. The biggest Auto Calibration registers value means the right value of ADC’s phase and frequency. MTL005 has two kinds of algorithms to calculate Auto Calibration’s value. One is traditional Difference method, another is MYSON’s proprietary method. It is suggested to use the latter one for better performance ¨ Histogram Histogram means the total number of input pixels below/above one threshold value, for individual R, G, B colors. This advanced function helps firmware to analyze ADC performance. Usually Firmware can use this information to measure ADC’s noise margin, adjust its offset and gain, or even aid in the mode detection. ¨ Min/Max Value Min/Max value means minimum or maximum pixel value within the specified input active image region for each RGB channel. This information is usually used to adjust ADC’s offset and gain. ¨ Pixel Grab Pixel Grab means users can grab a single input pixel at any one point. The position of the point can be programmed by users. This is another traditional method to measure ADC’s phase and frequency. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |