| Electronic Components Datasheet Search |
|
PIRD20.241 Datasheet(PDF) 2 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
PIRD20.241 Datasheet(HTML) 2 Page - PULS GmbH |
|
2 / 15 page ![]() PIRD20.241 PIANO-Series DC 12-28V, 20A, DUAL INPUT REDUNDANCY MODULE INDEX Page Page 1. Intended Use .......................................................3 2. Installation Requirements...................................3 3. Input and Output Characteristics .......................4 4. Power Losses........................................................5 5. Lifetime Expectancy and MTBF...........................5 6. Terminals and Wiring..........................................6 7. Functional Diagram.............................................6 8. Front Side and User Elements.............................7 9. EMC......................................................................8 10. Environment ........................................................9 11. Protection Features ...........................................10 12. Safety Features ..................................................10 13. Dielectric Strength ............................................10 14. Approvals .......................................................... 11 15. RoHS, REACH and Other Fulfilled Standards .. 11 16. Physical Dimensions and Weight ..................... 12 17. Application Notes............................................. 13 17.1. Using Only One Input Instead of Both Channels...............................................................13 17.2. Recommendations for Redundancy.........13 17.3. Inductive and Capacitive Loads................14 17.4. Use in a Tightly Sealed Enclosure ............14 17.5. Example: Redundancy for Controls .........14 17.6. Example: 1+1 Redundancy up to 10A......15 17.7. Example: 1+1 Redundancy up to 20A......15 The information given in this document is correct to the best of our knowledge and experience at the time of publication. If not expressly agreed otherwise, this information does not represent a warranty in the legal sense of the word. As the state of our knowledge and experience is constantly changing, the information in this data sheet is subject to revision. We therefore kindly ask you to always use the latest issue of this document (available under www.pulspower.com). No part of this document may be reproduced or utilized in any form without our prior permission in writing. TERMINOLOGY AND ABREVIATIONS DC 24V A figure displayed with the AC or DC before the value represents a nominal voltage with standard tolerances (usually ±15%) included. E.g.: DC 12V describes a 12V battery disregarding whether it is full (13.7V) or flat (10V) 24Vdc A figure with the unit (Vdc) at the end is a momentary figure without any additional tolerances included. may A key word indicating flexibility of choice with no implied preference shall A key word indicating a mandatory requirement should A key word indicating flexibility of choice with a strongly preferred implementation 1+1 Redundancy Use of two identical power supplies in parallel to provide continued operation following most failures in a single power supply. The two power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements. E.g. two 10A power supplies are needed to achieve a 10A redundant system. N+1 Redundancy Use of three or more identical power supplies in parallel, which are allowed to be connected in parallel for higher output currents, to provide continued operation following most failures in a single power supply. All power supply outputs should be isolated from each other by utilizing diodes or other switching arrangements. E.g.: To achieve a 40A redundant system, five 10A power supplies are needed in a N+1 redundant system. Ensure that the utilized power supplies are allowed to be connected in parallel to increase the output power. N+1 Redundancy 1+1 Redundancy AC DC AC DC AC DC AC DC AC DC AC DC IN 1 OUT IN 2 IN 1 OUT IN 2 IN 1 OUT IN 2 Load - AC DC AC DC Load - IN 1 OUT IN 2 Sep. 2016 / Rev. 1.0 DS-PIRD20.241 All parameters are specified at 24V, 20A output current, 25°C ambient and after a 5 minutes run-in time unless otherwise noted www.pulspower.com Phone +49 89 9278 0 Germany 2/15 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |