44 / 98 page ![]() 40 FDC Command Set Description (Continued) 3 If the Address Field ID comparison fails the controller sets ND in ST1 but continues to read the sector If there is a CRC error in the Address Field the controller sets CE in ST1 but continues to read the sector 4 Multi-track and Skip operations are not allowed SK and MT should be set to 0 5 If there is a CRC error in the Data Field the controller sets CE in ST1 and CD in ST2 but continues reading sectors 6 The controller reads a maximum of EOT physical sectors There is no support for multi-track reads Command Phase 0 MFM 0 0 0 0 1 0 IPS X X X X HD DR1 DR0 Track Number Drive Head Number Sector Number Bytes per Sector End of Track Sector Number Intersector Gap Length Data Length Execution Phase Data read from disk drive is transferred to system via DMA or non-DMA modes Result Phase Status Register 0 Status Register 1 Status Register 2 Track Number Head Number Sector Number Bytes per Sector 4113 Recalibrate Command The Recalibrate command is very similar to the Seek com- mand The controller sets the Present Track Register (PTR) of the selected drive to zero It then steps the head of the selected drive out until the TRK0 disk interface input signal goes active or until the maximum number of step pulses have been issued See Table 4-12 for the maximum recali- brate step pulse values based on the R255 and ETR bits in the Mode command If the number of tracks on the disk drive exceeds the maximum number of recalibrate step pulses another Recalibrate command may need to be is- sued TABLE 4-12 Maximum Recalibrate Step Pulses Based on R255 and ETR R255 ETR Maximum Recalibrate Step Pulses 0 0 85 (default) 1 0 255 0 1 3925 1 1 4095 After the last command byte is issued the DRx BUSY bit is set in the MSR for the selected drive The controller will simulate the Motor On time and then enter the Idle Phase The execution of the actual step pulses occur while the con- troller is in the Drive Polling Phase An interrupt will be gen- erated after the TRK0 signal is asserted or after the maxi- mum number of recalibrate step pulses are issued There is no Result Phase Recalibrates should not be issued on more than one drive at a time This is because the drives are actually selected via the DOR which can only select one drive at a time No other command except the Sense Inter- rupt command should be issued while a Recalibrate com- mand is in progress Command Phase 000001 1 1 000000DR1 DR0 Execution Phase Disk drive head is stepped out to Track 0 Result Phase None 4114 Relative Seek Command The Relative Seek command steps the selected drive in or out a given number of steps This command will step the readwrite head an incremental number of tracks as op- posed to comparing against the internal present track regis- ter for that drive Command Phase 1 DIR 0 0 1 1 1 1 X X X X X HD DR1 DR0 Execution Phase Disk drive head stepped in or out a pro- grammable number of tracks Result Phase None The Relative Seek parameters are defined as follows DIR ReadWrite Head Step Direction Control 0 e Step Head Out 1 e Step Head In RTN Relative Track Number This value will determine how many incremental tracks to step the head in or out from the current track number The controller will issue RTN number of step pulses and update the Present Track Register for the selected drive The one exception to this is if the TRK0 disk input goes active which indicates that the drive readwrite head is at the outermost track In this case the step pulses for the Relative Seek are terminated and the PTR value is set ac- cording to the actual number of step pulses issued The arithmetic is done modulo 255 The DRx BUSY bit in the MSR is set for the selected drive The controller will simu- late the Motor On time before issuing the step pulses After the Motor On time the controller will enter the Idle Phase The execution of the actual step pulses occurs in the Idle Phase of the controller After the step operation is complete the controller will gen- erate an interrupt There is no Result Phase Relative Seeks should not be issued on more than one drive at a time This is because the drives are actually selected via the DOR which can only select one drive at a time No other com- mand except the Sense Interrupt command should be is- sued while a Relative Seek command is in progress 44 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |