79 / 98 page ![]() 70 Parallel Port (Continued) 79 AUTOMATIC DATA TRANSFER (Modes 010 and 011) Automatic data transfer (ECP cycles generated by hard- ware) is supported only in modes 010 and 011 Automatic DMA access to fill or empty the FIFO is supported in modes 010 011 and 110 Mode 010 is for the forward direction only The direction bit is forced to 0 and PD0 – 7 is driven Mode 011 is for both the forward and backward directions The direction bit controls whether PD0 – 7 is driven Automatic Run Length Expanding (RLE) is supported in the backward direction Note 1 FIFO-full condition is checked before every expanded byte push Note 2 A pending DMA request is removed and a pending RLE expansion is aborted when switching from modes 010 or 011 to other modes Note 3 The two FIFO ports are neither synchronized nor linked together except via the empty and full FIFO status bits The FIFO shall not delay the push and pop operations even when they are performed concurrently Care must be taken not to corrupt PD0–7 or D0–7 while the other FIFO port is accessed Note 4 In the forward direction the empty bit is updated when the ECP cycle is completed not right after the last byte is popped out of the FIFO (valid cleared on cycle end) Note 5 ZWS is not asserted for DMA cycles Note 6 The one-bit commanddata tag is used only in forward direction 791 Forward Direction (Bit 5 of DCR e 0) When the ECP is in forward direction and the FIFO is not full (bit 1 of ECR is 0) the FIFO can be filled by software writes to the FIFO registers (AFIFO and DFIFO in mode 011 and CFIFO in mode 010) When DMA is enabled (bit 3 of ECR is 1 and bit 2 of ECR is 0) the ECP automatically issues DMA requests to fill the FIFO with normal data bytes When the ECP is in forward direction and the FIFO is not empty (bit 0 of ECR is 0) the ECP pops a byte from the FIFO and issues a write cycle to the peripheral device The ECP drives AFD according to the operation mode (ECR bits 5 – 7) and according to the tag of the popped byte as follows In Parallel Port FIFO mode (mode 010) AFD is controlled by bit 1 of DCR In ECP mode (mode 011) AFD is controlled by the popped tag AFD is driven high for normal data bytes and driven low for command bytes 792 ECP Forward Write Cycle An ECP write cycle starts when the ECP drives the popped tag onto AFD and the popped byte onto PD0 – 7 When BUSY is low the ECP asserts STB In 010 mode the ECP deasserts STB to terminate the write cycle In 011 mode the ECP waits for BUSY to be high When BUSY is high the ECP deasserts STB When BUSY is changed to low it changes AFD and PD0 – 7 TLC11930 – 20 FIGURE 7-6 ECP Forward Write Cycle 793 Backward Direction (Bit 5 of DCR is 1) When the ECP is in the backward direction and the FIFO is not full (bit 1 of ECR is 0) the ECP issues a read cycle from the peripheral device and monitors the BUSY signal If BUSY is high the byte is a data byte and it is pushed into the FIFO If BUSY is low the byte is a command byte The ECP checks bit 7 of the command byte if it is high the byte is ignored if it is low the byte is tagged as an RLC byte (not pushed into the FIFO but used as a Run Length Count to expand the next byte read) Following an RLC read the ECP issues a read cycle from the peripheral device to read the data byte to be expanded This byte is considered a data byte regardless of its BUSY state (even if it is low) This byte is pushed into the FIFO (RLCa1) times (ie RLCe0 push the byte once RLCe127 push the byte 128 times) When the ECP is in the backward direction and the FIFO is not empty (bit 0 of ECR is 0) the FIFO can be emptied by software reads from the FIFO register (only DFIFO in mode 011 no AFIFO and CFIFO read) When DMA is enabled (bit 3 of ECR is 1 and bit 2 of ECR is 0) the ECP automatically issues DMA requests to empty the FIFO (only in mode 011) 794 ECP Backward Read Cycle An ECP read cycle starts when the ECP drives AFD low The peripheral device drives BUSY high for a normal data read cycle or drives BUSY low for a command read cycle and drives the byte to be read onto PD0 – 7 When ACK is asserted the ECP drives AFD high When AFD is high the peripheral device deasserts ACK The ECP reads the PD0 – 7 byte then drives AFD low When AFD is low the peripheral device may change BUSY and PD0 – 7 states in preparation for the next cycle TLC11930 – 21 FIGURE 7-7 ECP Backward Read Cycle 710 FIFO TEST ACCESS (Mode 110) Mode 110 is used for testing the FIFO in PIO and DMA cycles Both read and write operations (pop and push) are supported regardless of the direction bit In the forward direction PD0 – 7 are driven but the data is undefined This mode can be used to measure the host- ECP cycle throughput usually with DMA cycles This mode can also be used to check the FIFO depth and its interrupt threshold usually with PIO cycles 79 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |