27 / 42 page ![]() DocID023298 Rev 2 27/42 L6758A Output voltage monitoring and protection 42 7 Output voltage monitoring and protection The L6758A monitors the regulated voltage of both sections through pin VSEN and SVSEN in order to manage OV and UV. The device shows different thresholds when in different operative conditions but the behavior in response to a protection event is still the same as described below. Protection is active also during soft-start while it is properly masked during DVID transitions with an additional delay to avoid false triggering. 7.1 Overvoltage When the voltage sensed by VSEN and/or SVSEN overcomes the OV threshold, the controller acts in order to protect the load from excessive voltage levels avoiding any possible undershoot. To reach this target, a special sequence is performed as per the following list: – The reference performs a DVID_Fast transition down to 250 mV on the section which triggered the OV protection. – The PWMs of the section which triggered the protection are switched between HiZ and zero (ENDRV is kept high) in order to follow the voltage imposed by the DVID_Fast on-going. This limits the output voltage excursion, protects the load and assures no undershoot is generated (if V OUT < 250 mV, the section is HiZ). – The PWMs of the non-involved section are set permanently to HiZ (ENDRV is kept low) in order to realize a HiZ condition. – OSC/ FLT pin is driven high. – Power supply or EN pin cycling is required to restart operations. If the cause of the failure is removed, the converter ends the transition with all PWMs in HiZ state and the output voltage of the section which triggered the protection lower than 250 mV. Table 12. L6758A protection at a glance Section Multi-phase Single-phase Overvoltage (OV) VSEN, SVSEN = +175 mV above reference. Action: IC Latch; DVIDFast to 250 mV, LS=ON & PWMx = 0 if required to keep the regulation to 250 mV; other section: HiZ. Undervoltage (UV) VSEN, SVSEN = 500 mV below reference. Active after Ref > 500 mV Action: IC Latch; both sections HiZ. Overcurrent (OC) Current monitor across inductor DCR. Dual protection, per-phase and average. Action: UV-Like. Dynamic VID Protection masked with additional delay to prevent from false triggering. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |