| Electronic Components Datasheet Search |
|
GF9101 Datasheet(PDF) 4 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
GF9101 Datasheet(HTML) 4 Page - List of Unclassifed Manufacturers |
|
4 / 23 page ![]() 520 - 64 - 7 4 PARALLEL LOADING If parallel loading is selected, both the COEF_WR pin and the LOAD_EN pin determine whether the GF9101 is in the load mode. When COEF_WR and LOAD_EN are both low, the load mode is selected, the run mode is disabled, and writes to memory can occur. Parallel loading is random access and synchronous. Data is written through COEF_DATA (7-0) and its destination is determined by COEF_ADDR (9-0). Coefficient memory is loaded by writing 8 bits at a time, first to two temporary registers (bits 15 -0) and finally to the desired memory bank (bits 23-0). Each memory bank word is loaded in three clock cycles. COEF_ADDR (9-7) defines the address location for temporary registers (TEMP_REG_A and TEMP_REG_B) and memory banks. COEF_ADDR (6-0) determines the filter coefficient address (0 -107) in the internal RAM. COEF_ADDR (6-0) must be less than 108. In Table 3, COEF_ADDR (9-7) determines the following: TEMP_REG_A and TEMP_REG_B temporarily hold memory bits, (7-0) and (15-8) respectively. Three 8 bit writes are necessary to write one 24-bit memory as follows: 1. Load COEF_DATA (7-0) into TEMP_REG_A 2. Load COEF_DATA (7-0) into TEMP_REG_B 3. Load COEF_DATA (7-0), TEMP_REG_B (7-0), and TEMP_REG_A (7-0) into the selected memory bank, MB0- MB5 (23-0). While COEF_ADDR (9-7) selects MB0-MB5 for writing, COEF_ADDR (6-0) selects the memory bank location that the 24-bit word is written into. Parallel loading is synchronous with CLK_IN. When COEF_WR and LOAD_EN are both low, 8-bit words will be written on the rising edge of CLK_IN. Consecutive writes may be done indefinitely by keeping COEF_WR and LOAD_EN low. A parallel loading timing diagram is shown in Figure 1. TABLE 1: Configuration Register Format CONFIGURATION REGISTER BIT COEF_DATA(6-0) MEANING 0 MODE A (1 if A input signed, 0 if unsigned) 1 MODE B (1 if B input signed, 0 if unsigned) 3, 2 DELAY_SEL selects delay for pipelining: Bits 3, 2 Delay in CLK_IN cycles 0, 0 1 0, 1 3 1, 0 4 1, 1 5 4 DATA_B_SEL 0 selects B12 for two 12 tap filters or one 24 tap filter by externally connecting DATA_A_OUT to DATA_B_IN. DATA_B_SEL 1 selects A12 for a 23 tap filter. 6,5 LOAD MODE SELECT (see below) Bits 6, 5 Loading mode 0, 0 Serial 0, 1 Parallel 1, 0 Microprocessor 1, 1 Reserved TABLE 2: Memory Locations for Internal RAM MEMORY BANKS (BITS) TAPS (BITS) 0 (23-12) 0 (11-0) 0 (11-0) 2 (11-0) 1 (23-12) 3 (11-0) 1 (11-0) 4 (11-0) 2 (23-12) 5 (11-0 2 (11-0) 6 (11-0) 3 (23-12) 7 (11-0) 3 (11-0) 8 (11-0) 4 (23-12) 9 (11-0) 4 (11-0) 10 (11-0) 5 (23-12) 11 (11-0) 5 (11-0) 12 (11-0) TABLE 3: Temporary Loading Registers and Memory Banks COEF_ADDR(9-7) (binary) DESTINATION NUMBER OF BITS 111 TEMP_REG_B 8 (15-8) 110 TEMP_REG_A 8 (7-0) 101 MB5 1 24 (23-0) 100 MB4 24 (23-0) 011 MB3 24 (23-0) 010 MB2 24 (23-0) 001 MB1 24 (23-0) 000 MB0 24 (23-0) NOTE 1: Memory Bank No. 5 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |