7 / 23 page ![]() 520 - 64 - 7 7 FILTER ARCHITECTURE For the following discussion on filter architecture, refer to the GF9101 Block Diagram and Figure 4. Fig. 4 Tap Cell (1-12) COEFFICIENT MULTIPLICATION AND ADDITION STAGE Two shift registers, A and B, are used to shift input data through the GF9101. Notice that if DATA_B_SEL was set low during configuration, data applied at DATA_A_IN enters at tap 1 and exits from tap 12, while data applied at DATA_B_IN enters at tap 12 and exits from tap 1. This gives two 12 tap filters. If DATA_B_SEL was set high during configuration, data applied at DATA_A_IN enters at tap 1, reverses direction at tap 12 (bypasses REG_12B) and exits from tap 1 on DATA_B_OUT, while DATA_B_IN is disabled. This gives a 23 tap filter. ENA and ENB control the shifting of the input data. The C register holds the next set of 12 input values to be applied to the multipliers. If ENC is high, SEL_A/B, determines whether the A or B shift register data enters the C register. SEL_A/B, also determines whether the MODE A or MODE B control signal enters the MULT_MODE register. The value in the MULT_MODE register determineswhether theinputdatato themultiplierisrecognized as signed or unsigned. MODE A and MODE B are separate, static control signals which determine signed/unsigned for A or B input data respectively. They are common to all taps. When using the GF9101 as a 23 or 24 tap filter (combiningREG_A and REG_B to get a single filter output), MODE A and MODE B should be in the same state. If not, a signed/unsigned mismatch will occur. One needs to be cautious while using the GF9101 as two separate filters with MODE A and MODE B not in the same state (data entering REG_A is signed/ unsigned while in REG_B it is the opposite of REG_A) . If ENC is low and SEL_A/B, changes state, a signed/unsigned mismatch will occur. To avoid an error under these circumstances, always make ENC high after a SEL_A/B, state change. The input values in the C register are multiplied by the coefficient values in the COEF register and the result enters an adder tree . The coefficients that enter the COEF register are stored in the internal RAM and are selected by the externally controlled COEF_ADDR (6-0) bus, which is common to all taps. At the output of the adder tree is the untruncated sum of taps 1 through 12. This sum is then truncated as shown in the GF9101 Block diagram. The sum then passes through a variable delay along with the ZERO and NEGATE signals. The variable delay is provided so that complementary sums from cascaded GF9101’s may be added together in the pipelined output stage. The ZERO signal zeros the sum and the NEGATE signal negates the sum. DATA _A_IN +10.0 CONFIGURATION REGISTER ENA TO NEXT TAP ENB ENC 1 0 +10.0 +10.0 +10.0 ±10.11 ±10.11 TO ADDER DATA_B_IN TO NEXT TAP B REG C REG MULT REG COEF REG 108 x12 COEF REG +10.0 / ±9.0 MULT MODE REG SIGNED / UNSIGNED A REG +10.0 +10.0 ±0.11 ±0.11 MODE A MODE B 7 COEF–ADDR 1 0 SEL–A/B R R R R R |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |