| Electronic Components Datasheet Search |
|
LTC4211CS8 Datasheet(PDF) 15 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC4211CS8 Datasheet(HTML) 15 Page - Linear Technology |
|
15 / 36 page ![]() 15 LTC4211 4211f a start-up check to make sure the supply voltage is above its 2.3V UVLO threshold (see Time Point 1). If the input supply voltage is valid, the gate of the external pass transistor is pulled to ground by the internal 200 µAcurrent source connected at the GATE pin. The TIMER pin is held low by an internal N-channel pull-down transistor (see M6, LTC4211 Block Diagram) and the FILTER pin voltage is pulled to ground by an internal 10 µA current source. Once VCC and ON (the ON pin is >1.316) are valid, the LTC4211 checks to make sure that GATE is OFF (VGATE < 0.2V) at Time Point 2. An internal timing circuit is enabled and the TIMER pin voltage ramps up at the rate described by Equation 1. At Time Point 3 (the timing period pro- grammed by CTIMER), the TIMER pin voltage equals VTMR (1.236V). Next, the TIMER pin voltage ramps down to Time Point 4 where the LTC4211 performs two checks: (1) FILTER pin voltage is low (VFILTER < 1.156V) and (2) FAULT pin voltage is high (VFAULT > 1.286V). If both conditions are met, the LTC4211 begins a second timing (soft-start) cycle. Second Timing (Soft-Start) Cycle At the beginning of the second timing cycle (Time Point 5), the LTC4211’s FAST COMP is armed and an internal 10 µA current source working with an internal charge pump provides the gate drive to the external pass transistor. An expression for the GATE voltage slew rate is given by Equation 3: V Slew Rate dV dt A C GATE GATE GATE , = µ 10 (3) where CGATE = Power MOSFET gate input capacitance (CISS). For example, a Si4410DY (a 30V N-channel power MOSFET) exhibits an approximate CGATE of 3300pF at VGS = 10V. The LTC4211’s GATE voltage rate-of-change (slew rate) for this example would be: V Slew Rate dV dt A pF V ms GATE GATE ,. = µ = 10 3300 303 The inrush current being delivered to the load while the GATE is ramping is dependent on CLOAD and CGATE. Equation 4 gives an expression for the inrush current during the second timing cycle: I dV dt CA C C INRUSH GATE LOAD LOAD GATE == µ •• 10 (4) For example, if CGATE = 3300pF and CLOAD = 2000µF, the inrush current charging CLOAD is: IA F F A INRUSH =µ µ µ = 10 2000 0 0033 606 • . . (5) At Time Point 6, the output voltage trips COMP2’s thresh- old, signaling an output voltage “power good” condition. At Time Point 7, RESET is asserted high, SLOW COMP is armed and the LTC4211 enters a fault monitor mode. The TIMER voltage then ramps down to Time Point 8. Power-Off Cycle As shown at Time Point 9, an external hard reset is initiated by pulling the ON pin low (VON < 1.236V). The GATE pin voltage is ramped to ground by the internal 200 µA current source, discharging CGATE and turning off the pass tran- sistor. As CLOAD discharges, the output voltage crosses COMP2’s threshold, signaling a “power bad” condition at Time Point 10. At this point, RESET is asserted low. SOFT-START WITH CURRENT LIMITING During the second timing cycle, the inrush current was described by Equation 4. Note that there is a one-to-one correspondence in the inrush current to CLOAD. If the inrush current is large enough to cause a voltage drop greater than 50mV across the sense resistor, an internal servo loop controls the operation of the 10 µA current source at the GATE pin to regulate the load current to: I mV R LIMIT SOFTSTART SENSE () = 50 (6) For example, the inrush current is limited to 5A when RSENSE = 0.01Ω. OPERATIO |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |