26 / 46 page ![]() CS5461 26 DS546PP2 be set to a value much higher than the EOUT pulse rate. The FOUT pin outputs negative and positive ener- gy, but has no energy direction indicator. The max- imum FOUT pulse frequency is set by the value in the PulseRateF Register. 5.4 Anti-Creep for the Pulse Outputs Anti-Creep can be enabled/disabled for both EOUT/EDIR and FOUT pulse output systems in the Control Register. Anti-creep allows the elec- tronic meter to maintain a “buffer” energy band, defined by positive/negative energy threshold lev- els, such that when the magnitude of the accumu- lated energy is below this level, no energy pulses are issued. The anti-creep feature is especially use- ful when the meter demands that the energy pulse outputs are set to relatively high frequency. A high- er frequency pulse rate means that less energy reg- istration is required to generate a pulse; and so it is more likely that random noise present in the power line and/or current-sense circuit can generate a pulse that does not represent billable energy. 5.5 Design Examples EXAMPLE #1: For a power line with maximum rated levels of 250 V (RMS) and 20 A (RMS), the pulse-frequency on the EOUT pin needs to be ‘IR’ = 100 pulses-per-second (100 Hz) when the RMS-voltage and RMS-current levels on the power line are 220 V and 15 A respectively. To meet this requirement, the pulse-rate frequency (‘PR’) in the Pulse-Rate Register must be set accordingly. After calibration, the first step to finding the value of ‘PR’ is to set the voltage and current sensor gain constants, KV and KI, such that there will be accept- able voltage levels on the CS5461 inputs when the power line voltage and current levels are at the maximum values of 250 V and 20 A. KV and KI are needed to determine the appropriate ratios of the voltage/current transformers and/or shunt resistor values to use in the front-end voltage/current sen- sor networks. For a sinewave, the largest RMS value that can be accurately measured (without over-driving the in- puts) will register ~0.707 of the maximum DC in- put level. Since power signals are often not perfectly sinusoidal in real-world situations, and to provide for some over-range capability, the RMS Voltage Register and RMS Current Register is set to measure 0.6 when the RMS-values of the line-voltage and line-current levels are 250 V and 20 A. Therefore, when the RMS registers measure 0.6, the voltage level at the inputs will be 0.6 x 250 mV = 150 mV. The sensor gain con- stants, KV and KI, are determined by demanding that the voltage and current channel inputs should be 150 mV RMS when the power line voltage and current are at the maximum values of 250 V and 20 A. KV = 150 mV / 250 V = 0.0006 KI = 150 mV / 20 A = 0.0075 Ω These sensor gain constants are used to calculate what the input voltage levels will be on the CS5461 inputs when the line-voltage and line-current are 220 V and 15 A. These values are VVnom and VIn- om. VVnom =KV * 220 V = 132 mV VInom =KI * 15 A = 112.5 mV The pulse rate on EOUT will be at ‘PR’ pulses per second (Hz) when the RMS-levels of voltage/cur- rent inputs are at 250 mV. When the voltage/cur- rent inputs are set at VVnom and VInom, the pulse rate needs to be ‘IR’ = 100 pulses per second. IR will be some percentage of PR. The percentage is defined by the ratios of V Vnom/250 mV and V Inom/250 mV with the following formula: PulseRate IR PR V Vnom 250mV ------------------- V Inom 250mV ------------------- ⋅⋅ == |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |