| Electronic Components Datasheet Search |
|
CS5461 Datasheet(PDF) 37 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS5461 Datasheet(HTML) 37 Page - Cirrus Logic |
|
37 / 46 page ![]() CS5461 DS546PP2 37 7.9 Power Offset Register Address: 14 Default** = 0.000 This offset value is added to each power value that is computed for each voltage/current sample pair before being accumulated in the Energy Register. This register can be used to offset contributions to the energy result that are caused by undesirable sources of energy that are inherent in the system. This value is in two’s comple- ment notation. 7.10 Status Register and Mask Register Address: 15 (Status Register); 26 (Mask Register) Default** = 0x000000 (Status Register) 0x000000 (Mask Register) The Status Register indicates the condition of the chip. In normal operation writing a '1' to a bit will cause the bit to go to the '0' state. Writing a '0' to a bit will maintain the status bit in its current state. With this feature the user can simply write to the Status Register to clear the bits that have been seen, without concern of clearing any newly set bits. Even if a status bit is masked to prevent an interrupt, the status bit will still be set in the Status Register. The Mask Register is used to control the activation of the INT pin. Placing a logic '1' in the Mask Register will allow the corresponding bit in the Status Register to activate the INT pin when the status bit is asserted. DRDY Data Ready. When running in single or continuous conversion acquisition mode, this bit will in- dicate the end of computation cycles. When running calibrations, this bit indicates the end of a calibration sequence. EOUT Indicates that the energy limit has been reached for the EOUT Energy Accumulation Register, and so this register will be cleared, and one pulse will be generated on the EOUT pin (if en- abled). If EOUT is asserted, this bit will be cleared automatically just after the beginning of any subsequent A/D conversion cycle in which no EOUT pulses need to be issued. The bit can also be cleared by writing to the Status Register. This status bit is set with a maximum frequency of 4 kHz (when MCLK/K is 4.096 MHz). When MCLK/K is not equal to 4.096 MHz, the user should scale the pulse-rate would be expected with MCLK/K = 4.096 MHz by a factor of 4.096 MHz / (MCLK/K), to get the actual pulse-rate. EDIR Set whenever the EOUT bit is asserted as long as the energy result is negative. Reset/Clear behavior of the EDIR status bit is similar to the EOUT status bit. IOR Current Out of Range. Set when the magnitude of the calibrated current value is too large or too small to fit in the Instantaneous Current Register. MSB LSB -(20)2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 2-23 23 22 21 20 19 18 17 16 DRDY EOUT EDIR CRDY IOR VOR 15 14 13 12 11 10 9 8 IROR VROR EOOR 7 654 32 10 VOD IOD LSD VSAG IC |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |