Back Button FS9721B Datasheet HTML 6Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 7Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 8Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 9Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 10Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 11Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 12Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 13Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 14Page - Fortune Semiconductor Corp. Next Button
Zoom Inzoom in Zoom Outzoom out
 10 / 35 page
background image
FS9721B
Rev. 1.7
10/35
Capacitor Measurement Accuracy
after Zero Input Relative
To Adjust by 250.0nF Mode
2.500nF Mode
5%+2
5
Counts
25.00 nF Mode
2%+1
0
Counts
250.0 nF Mode
0.5%
+3
Counts
2.500 μF Mode
1%+2
Counts
25.00 μF Mode
1.5%
+2
Counts
*1 In the duty cycle measurement, we have to input square waves. The main error of the measurement is due
to the error of the pulse width that the comparator can resolve. Suppose the error is 100ns and the input
frequency is 100KHz. We can divide the square wave into 1000 segments (1000 counts), and thus each
count takes 10 ns. Therefore the maximum error in Duty Cycle measurement is (100ns/10ns)=10 Counts.
50% duty cycle signal can be measured to 50.0%±1.0%. The signal may not be measured if the duty cycle
is more than 99% or less than 1%, and the measurement will display 0.00%.
10
Measurement Mode Selection
10.1 Measurement Mode Selection (MEA1〜MEA4 is “1” for empty, and “0” for connect to VSS)
M
E
A
4
M
E
A
3
M
E
A
2
M
E
A
1
Measurement Function
and
Select Key Function
Switch
Hz/Duty
Rel
Hold
Range
Select
Jump
1
1
1
1
DCV/A
CV
②
DCV/ACV
Switch
Hz/Duty
Voltage
Switch
●
●
●
●
J4
1
1
0
1
Ohm/Di
ode/
Continu
ity
/Cap.
CAP=1:
Ohm/Diode/
Cont. Switch
CAP=0:
Ohm/Diode/
Cont./Cap.
Switch
●
●
Ohm●
●
J3,
J5
1
0
1
0
DCV
No mV
Mode
V/Hz/Duty
Switch
●
●
●
J4
1
0
0
1
ACV
V/Hz/Duty
Switch
●
●
●
J4
1
0
1
1
DCmV
mV/Hz/Duty/
Switch
●
●
J3
1
0
0
0
10A
DCA/ACA
Switch
A/Hz/Duty
Switch
●
●
●
●
1
1
1
0
mA
DCmA/ACm
A
Switch
mA/Hz/Duty
Switch
●
●
●
●
J1
1
1
0
0
μA
DCμA/AcμA
Switch
μA/Hz/Duty
Switch
●
●
●
●
J2
0
1
1
1
Cap
●
●
J3, J5
0
1
0
1
Hz/Dut
y
③
Hz/Duty
Switch
●
J6
0
0
1
1
Input
from
ADP
0
0
1
0
0
0
0
1



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com