Back Button FS9721B Datasheet HTML 7Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 8Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 9Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 10Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 11Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 12Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 13Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 14Page - Fortune Semiconductor Corp. FS9721B Datasheet HTML 15Page - Fortune Semiconductor Corp. Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 35 page
background image
FS9721B
Rev. 1.7
11/35
0
0
0
0
Please
Refer
to Form
10.2
0
1
1
0
Input
from
ADP
④
Note: ① The “JX” in Jump column means the JX of the measurement function is open circuit in the diagram
that common used by diagram 6 and 7.
②
In Auto mode, the ACmv Measurement of ACV mode can be selected only when the Range key is
pressed.
③
This mode uses ADP path input to measure Hz/Duty.
④
ADP can auto-range for 240.0mV/24.00mV, and display 2400 and 240.0, respectively.
10.2 Determination of ADP Input and Self-defined Symbol and Decimal Location
(MEA1〜MEA4 is “1” for empty, and “0” for connect to VSS)
MEA4
MEA3
MEA2
MEA
1
Range of Input
Voltage
Input
Channel
Decimal
Location
Symbol
Location
Symbol
0
0
1
1
±240mV
ADP
2400
Set
by
LCDC1 and
LCDC2
User-D
efined
0
0
1
0
240.0
0
0
0
1
24.00
0
0
0
0
2.400
10.3 Use the Combination of LCDC1 and LCD2 to Determine the Self-defined Symbol Location
in LCD
(LCDC1 and LCDC2 is “1” for empty, and “0” for connect to VSS)
LCDC1
LCDC2
Symbol
Location
Description
0
0
COM1, SEG14
User Defines Symbol
1
0
COM2, SEG14
0
1
COM3, SEG14
1
1
COM4, SEG14
10.4 The Function of ADPC1 and ADPC2 in ADP Input
(ADPC1 and ADPC2 is “1” for empty, and “0” for connect to VSS)
ADPC1
ADPC2
DC/AC Status
ADP
Maximum Input
Voltage
1
1
DC
240mV
1
0
AC
0
1
DC
24mV
0
0
AC



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com