28 / 37 page ![]() Digital Control・ ・ ・ ・Non-Isolated POL DC-DC Converter BDX Series 28 Bellnix DC-DC Converter BDD20190530_C02 TON_RISE 61h R/W Word 2 Direct (m = 1, b = 0, R = 3) ms 03E8h (1.000ms) TOFF_DELAY 64h R/W Word 2 Direct (m = 1, b = 0, R = 2) ms 0000h (0.00ms) TOFF_FALL 65h R/W Word 2 Direct (m = 1, b = 0, R = 3) ms 03E8h (1.000ms) READ_VOUT 8Bh Read Word 2 Direct (m = 1, b = 0, R = 0) mV ― READ_IOUT 8Ch Read Word 2 Direct (m =1/3, b = 0, R = 1) A ― *1) The proper names of data formats in the transaction type indicated in the previous page are described below. Transaction type Communication protocol Send Byte Send Byte Protocol Read Byte Read Byte Protocol Read Word Read Word Protocol Write Word Write Word Protocol R/W Byte Read Byte Protocol and Write Byte Protocol R/W Word Read Word Protocol and Write Word Protocol 9-6-2 PAGE command (00h) This is used for switching control objects of commands which are described in 9-6-1 -2) 3). Meanings of each bit are described as below. Bit No. Purpose Value Description Default setting 7-0 To switch the separate commands of VOUT1, VOUT2 control object 00000000 VOUT1 ● 00000001 VOUT2 9-6-3 ON_OFF_CONFIG command (02h) This command is used to set the ON/OFF control operations. Meanings of each bit are described below. Bit No. Purpose Value Description Default setting 7–5 — 000 Unavailable ● 4-2 To select “ENABLE” or “DISABLE” of the ON/OFF control 000 Select “Disable” of the ON/OFF control via PMBus communication and ON/OFF1 pin (Always set to ON) 101 “Enable” ON/OFF1 pin, “Disable” PMBus communication ● 110 “Disable” ON/OFF1 pin, “Enable” PMBus communication 111 “Enable” ON/OFF1 pin and PMBus Communication *1 1 — 1 Positive logic (Output is ON when opened) ● 0 To select “ENABLE” or “DISABLE” of turn-off sequence when output is turned off via the ON/OFF1 pin 0 Output is turned off via a sequence configured by TOFF_DELAY and TOFF_FALL. ● 1 Switching stops immediately *1 ON/OFF control by ON/OFF1 pin, PMBus communication is AND operation (see 8-7-2 ). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |