24 / 71 page ![]() 7.4.1.2 Auto Conversion Mode The auto conversion mode is a programmable feature in bus powered mode that can be enabled by setting the CONV_MODE_SEL as '10b' in the device configuration-1 register. As shown in Figure 7-14, the host can skip the issue of the temperature conversion request and directly read the temperature data from the device when the auto conversion mode is enabled. This enables the application to speed up the temperature conversion and read, because the request command is no longer required. As in the case for multiple device bus, a low impedance current path is required to meet the current requirement of the bus during the active conversions. Reset Answer to Reset MATCHADDR READ SCRATCHPAD-1 Start of Conversion Ac ve conversion me (tACT) Shutdown Shutdown Temperature Conversion Bus Communica on Command startup delay (tDELAY) Figure 7-14. Auto Conversion Mode 7.4.1.3 Stacked Conversion Mode The stacked conversion mode is a programmable feature in bus powered mode that can be enabled by setting CONV_MODE_SEL as '01b' in the device configuration-1 register. As shown in Figure 7-15, the devices can use the address programmed in the short address register to delay the temperature conversion for the devices when the stacked conversion mode is enabled. No more than two devices are actively converting at any given time, therefore the current drain in bus powered configuration is limited. This allows the application to avoid simultaneous temperature conversion by multiple parts and reducing the user system maximal supply current. Reset Answer to Reset SKIPADDR CONVERT TEMP Start of Conversion Shutdown Temperature Con version Sequen ce Bu s C ommunication TMP18xx SHORT ADDRESS = 0 TMP18xx SHORT ADDRESS = 1 TMP18xx SHORT ADDRESS = 2 Temperature conversion delay (tDELAY) Note The host controller must program all the device with the same setting for CONV_TIME_SEL and AVG_SEL to ensure that no more than two devices are actively converting to use the feature as it is intended. Figure 7-15. Stacked Conversion Mode 7.4.1.4 Continuous Conversion Mode The continuous conversion mode is applicable only in VDD powered mode of operation for the device. This mode can be enabled by writing a value other than '000b' to CONV_MODE_SEL bits in the device configuration-1 register. As shown in Figure 7-16, the device can perform periodic conversions at the interval programmed TMP1826 SBOSA45A – FEBRUARY 2022 – REVISED SEPTEMBER 2022 www.ti.com 24 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated Product Folder Links: TMP1826 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |