| Electronic Components Datasheet Search |
|
LP5860 Datasheet(PDF) 20 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LP5860 Datasheet(HTML) 20 Page - Texas Instruments |
|
20 / 56 page ![]() Comparing with Mode 1, Mode 2 and Mode 3 provide a better synchronization when multiple LP5860T devices used together. A high-level pulse width longer than tSYNC_H is required at the beginning of each VSYNC frame. Figure 8-9 shows the VSYNC connections and Figure 8-10 shows the timing requirements. MCU LP586x LP586x GPIO SYNC SYNC Figure 8-9. Multiple Devices Sync fVSYNC t>tVSYNC_H Figure 8-10. VSYNC Timing Table 8-4 is the summary of the 3 data refresh modes. Table 8-4. Data Refresh Mode MODE TYPE PWM RESOLUTION PWM OUTPUT EXTERNAL VSYNC Mode 1 8 Bits Data update instantly No Mode 2 8 Bits Data update by frame Yes Mode 3 16 Bits 8.3.6 Full Addressable SRAM SRAM is implemented inside the LP5860T device to support data writing and reading at the same time. Although data refresh mechanisms are not the same for Mode 1 and Mode 2/3, the data writing and reading follow the same method. Uses can update partial of the SRAM data only or the whole SRAM page simultaneously. The LP5860T supports auto-increment function to minimize data traffic and increase data transfer efficiency. Please be noted that 16-bit PWM (Mode 3) and 8-bit PWM (Mode 1 and Mode 2) are assigned with different SRAM addresses. 8.3.7 Protections and Diagnostics LED Open Detection The LP5860T includes LED open detection (LOD) for the fault caused by any opened LED dot. The threshold for LED open is 0.25-V typical. LED open detection is only performed when PWM ≥ 25 (Mode 1 and Mode 2) or PWM ≥ 6400 (Mode 3) and voltage on CSn is detected lower than open threshold for continuously 4 sub-periods. Figure 8-11 shows the detection circuit of LOD function. When open fault is detected, 'Global_LOD' bit in Fault_state register is set to 1 and detailed fault state for each LED is also monitored in register Dot_lodx (x = 0, 1, … , 32). All open fault indicator bits can be cleared by setting LOD_clear = 0Fh after the open condition is removed. LOD removal function can be enabled by setting 'LOD_removal' bit in Dev_config2 register to 1. This function turns off the current sink of the open channel when scanning to the line where the opened LED is included. LP5860T SNVSCE1 – MAY 2023 www.ti.com 20 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated Product Folder Links: LP5860T |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |